Cluster Settings
Reference for all VergeOS cluster configuration settings, including CPU type, RAM allocation, security mitigations, compute resource policies, swap, and node temperature monitoring.
The Cluster Settings form enables you to configure key parameters relating to performance, security, allocation, thermal monitoring, and swap. While the majority of default settings are appropriate for most environments, it's recommended to review them when creating a new cluster and periodically thereafter to ensure alignment with your organization's policies and operational requirements.
Most cluster setting changes will require a reboot of each cluster node. A message will appear at the top of the cluster dashboard when a reboot is necessary. Select the Need Restart option (within the reboot/restart message at the top of the cluster dashboard or left menu option) to manage reboots of the cluster nodes. Always follow proper Maintenance Mode procedures when rebooting nodes to avoid workload disruptions.
Accessing Cluster Settings
From the top menu, navigate to Infrastructure > Clusters > double-click the desired cluster
Click Edit on the left menu.
Cluster
This section defines the fundamental properties of your cluster.
Enabled: By default, the cluster will be enabled. Typically, there is no reason to disable it; however, doing so may be useful in certain situations, such as during a complete cluster reconfiguration.
Name: A cluster is typically named during installation but can be renamed without issue.
Description: Optional text area to provide a brief description of the cluster's purpose or characteristics.
Default CPU Type: Defines the default/recommended CPU type for virtual machines with this cluster designated. This setting is automatically selected during cluster installation, based on detected CPU hardware. During initial configuration, review the setting to verify accurate CPU type was detected.
To accommodate migration/failover of virtual machines to another cluster using a lower class of CPU chip, Default CPU type can be changed to the lower class type to allow virtual machines to be ported to the older chip hardware without issue.
All nodes within a cluster should contain the same CPU hardware; mixed CPU types within the same cluster can cause performance and workload migration issues.
Storage buffer per node (default 2 GB): The amount of additional RAM to allocate per node for vSAN performance caching.
Cluster Security/Performance
This subsection allows you to enable/disable various performance and security-related features and mitigations for all nodes in the cluster.
Allocate Hugepages for Storage (default enabled): Enabling hugepages is strongly recommended in most cases, as it enhances memory storage performance for workloads. Disabling this setting is generally discouraged, except in rare scenarios, such as when running only very small virtual machines or legacy guest operating systems with limited hugepage support.
Disable CPU Security Mitigations: If selected, kernel-level CPU security mitigations are disabled for the cluster.
IMPORTANT: Although disabling CPU security mitigations can improve performance, this can be risky. Only select this option when you completely trust all guests running in this cluster and can be sure the workloads have no external vulnerabilities (e.g. airgapped systems).
Disable Speculative Store Bypass: If selected, disables Speculative Store Bypass (SSB) at runtime. Disabling SSB can result in a modest to moderate performance drop, depending on system workloads.
Disable SMT: If selected, disables simultaneous multi-threading (SMT) at runtime.
Disable sleep states for CPUs: If selected, VergeOS automatically disables low level sleep state(s). This can eliminate unnecessary sleep state transitions due to short idle bursts that would otherwise cause a notable drop in performance with minimal benefit in power efficiency.
Enable Split Lock Detection: Detects split lock events within workloads and reports them in the system log. Enabling this option can have a performance impact on virtual machines that trigger a split lock.
Energy-Performance Policy (default=Performance): Policy setting that guides the processor’s internal logic to balance performance vs. power efficiency. This setting is typically best left at its default, allowing the system to dynamically optimize for performance at runtime. Alternative energy-versus-performance options are available to support non-enterprise environments such as consumer-grade systems, home labs, or proof-of-concept (POC) deployments.
CPU Scaling Governor (default=Performance): Policy for kernel-level, dynamic CPU frequency adjustment based on system load. This setting is typically best left at its default, allowing the system to dynamically optimize for performance at runtime. Alternative energy-versus-performance options are available to support non-enterprise environments such as consumer-grade systems, home labs, or proof-of-concept (POC) deployments.
System Log Filter
System Log Filter (default
*:3,ipmievd:5,rasdaemon,!ntpd,!postfix): A comma-separated list of filters in rsyslog syntax that determines which log entries to display in the user interface. Entries matching these filters are shown; all others are excluded from the UI view. This syntax supports facility and priority filters, as well as program-specific inclusions or exclusions.
Unfiltered logs remain accessible via Node Diagnostics (Navigate to Nodes > double-click the desired node > select Diagnostics from the left menu.)
Compute
This section configures compute resource policies for your cluster. These settings will not apply for storage-only clusters.
Max RAM per machine: Specifies the maximum amount of RAM that can be allocated to a single workload (such as a virtual machine, tenant node, or NAS service).
Considerations
If any running workloads (e.g. VMs) are using more RAM than this limit, they will be unable to migrate after the setting is lowered.
The limit affects workload startup and migration (i.e., starting on a new node). It does not prohibit you from creating a workload with more RAM, but only prevents it from starting if the limit is exceeded.
As a general rule, choose the lowest RAM value that still meets the needs of your largest expected workload. Lower RAM allocations to individual workloads will maximize flexibility for migrations, failovers, and workload portability and enable faster failover times.
Be cautious when setting this limit close to a node's physical RAM capacity. If you set this limit to match a node's total RAM (e.g., 128GB) and then create a VM using that full amount, the VM will be unable to start or migrate because:
VergeOS reserves RAM for system operations and vSAN functionality
During maintenance or failover, workloads must migrate to other available nodes
A VM consuming nearly all available RAM cannot successfully migrate to another node
Recommended approach: Set this limit to no more than 70-80% of your smallest node's physical RAM, ensuring VMs can always migrate during maintenance or failover scenarios.
Max cores per machine: Specifies the maximum number of CPU cores that can be allocated to a single workload (such as a virtual machine, tenant node, or NAS service)
Considerations
If any running workloads (e.g. VMs) are using more cores than this limit, they will be unable to migrate after the setting is lowered.
In nearly all cases, this value should not exceed the number of cores available within a single CPU socket.
This value should never exceed the total number of physical cores in a single node
Target max ram pct (default 80): Specifies the maximum percentage of physical RAM that a cluster node should use under normal conditions. This threshold helps prevent over-allocation from new workloads. However, it may be exceeded in special circumstances such as failover or workload migration to maintain service continuity.
% of reserve ram to use for machines: defines a portion (in percentage) of swap reserved specifically to simulate additional workload RAM when physical RAM is exhausted. This virtual RAM can be configured as a fallback for RAM overprovisioning.
RAM Overprovisioning Cautions
Using this reserve RAM feature is typically only intended as a fallback for RAM overprovisioning
Avoid overprovisioning on clusters with high workload memory utilization or critical workloads
Consider rightsizing VMs by reducing RAM allocations where usage is consistently low
If too many VMs demand their full memory allocation simultaneously, workload performance may be degraded as virtual RAM is orders of magnitude slower than physical RAM (milliseconds vs. nanoseconds)
Nested Virtualization: Enables using a virtual machine inside another virtual machine using hardware acceleration from the host.
Allow Nested Virtualization Live Migration:* Allows live migration of virtual machines with nested virtualization.
Allow VGPU Live Migration:* Allows virtual machines with vGPU devices to be live migrated (experimental). Although not fully verified in testing, live migration of vGPU workloads has been seen to generally work reliably when the latest NVIDIA drivers are used on both host and guest.
*Live Migrations
The virtual machine setting: Migration Method allows defining migration behavior per VM (e.g. require manual shutdown, attempt live migration)
Enabling Nested Virtualization
Nested virtualization requires two settings; it must be enabled for the cluster and at the VM level:
Cluster level: Enable the Nested Virtualization setting in the list above. If a restart message appears at the top of the cluster dashboard, reboot the cluster nodes using proper Maintenance Mode procedures.
VM level: From the VM dashboard, click Edit and enable Nested Virtualization in the VM settings.
Restart the VM after you enable both settings. The CPU feature is applied when the VM starts.
Hyper-V Use Case
Running Hyper-V inside a Windows guest is a common reason to enable nested virtualization. When nested virtualization is not enabled at both levels, the Hyper-V role can cause the guest to enter a boot loop shortly after the Windows logo appears. If the Hyper-V role still fails after a restart, power the VM fully off and back on. Running Hyper-V as a nested guest is suitable for lab and testing scenarios; it is not a production-certified configuration.
Storage (Swap Settings)
Swap settings are specified during cluster installation. Swap setting changes will only apply to newly formatted disks.
Tier used for swap: Storage tier to be used for swap space. Swap is disabled when value is 0
Swap per drive: Amount of swap space to allocate per drive
Node Temperature
This section allows you to define settings for VergeOS alerting behavior related to higher CPU thermal readings on cluster nodes. Timely notification, in advance of reaching CPU max temperatures, can allow taking actions to avoid outages and harm to physical equipment; allowing CPU hardware to reach its maximum temperature limits can cause the CPU to automatically shut itself down or cause hard locks, and potential hardware damage.
Maximum Core Temperature (Celsius) Establishes a peak temperature to use for VergeOS temperature monitoring (used in combination with the next setting: Maximum Core Temperature Warning Threshold %).
query from hardware (default) - retrieves the hardware-defined maximum temperature from the CPU
custom - allows for manually defining a specific peak temperature. Refer to your hardware documentation to verify your CPU max temperature.
disable - this selection can be used when you do not wish to monitor temperature within VergeOS (when you are not responsible for monitoring the hardware, e.g. bare metal provider, or VergeOS is running within a virtual environment)
Maximum Core Temperature Warning Threshold % Sets a percentage boundary relative to the maximum core temperature (above) at which to trigger a warning state. A warning state will cause a yellow node status and system log warning entry will be created. Typically, a threshold of at least 10% or higher is recommended to allow time to take proper measures in reaction to a thermal issue.
Critical Core Temperature (Celsius): Defines temperature at which to trigger an error state in VergeOS. When reported hardware temperatures reach this temperature, the node status will turn to red and an error entry will appear in the system log.
query from hardware (default) - retrieves the hardware-defined critical temperature from the CPU
custom - allows for manually defining a critical temperature. Refer to your hardware documentation to verify your CPU max temperature.
disable - this selection can be used when you do not wish to monitor temperature within VergeOS (when you are not responsible for monitoring the hardware, e.g. bare metal provider, or VergeOS is running within a virtual environment)