Understanding vSAN Redundancy Levels

Learn about VergeOS vSAN N+1 and N+2 redundancy levels, their requirements, use cases, and considerations

Overview

Key Points

  • N+1 / RF2 (default) maintains 2 copies of every data block and can survive one simultaneous node failure. N+1 provides robust protection suitable for most production environments.

  • N+2 / RF3 maintains 3 copies of every data block and can survive two simultaneous failures.

  • Redundancy is configured per system and applies per vSAN tier.

VergeOS vSAN supports configurable redundancy levels — also known as Replication Factors (RF) — that determine how many copies of each data block are maintained across the system. Choosing the right level is a balance between fault tolerance, storage overhead, and infrastructure cost.

N+1 Redundancy (RF2)

N+1 redundancy maintains 2 copies of every data block in the vSAN. This allows a cluster to survive one simultaneous failure — either a node failure or drive failures within a single node.

Requirement
Detail

Minimum Nodes

2 controller nodes

Copies of Data

2

Storage Overhead

~2x (before deduplication)

When to Use N+1

VergeOS N+1 is the default configuration and well suited for most scenarios. It provides a strong balance between capacity efficiency and fault tolerance and is appropriate for many production environments when combined with best practices for data protection such as regular snapshots and off-site data replication.

N+2 Redundancy (RF3)

N+2 vSAN redundancy is available for environments that have a specific requirement to maintain 3 copies of every data block and/or for a system to survive two simultaneous failures. N+2 can survive two simultaneous node failures, disk failures across two nodes, or a combination of both.

Requirement
Detail

Minimum Nodes

3 (all controller nodes)

Recommended Nodes

5 (provides a witness node to completely avoid split-brain scenarios)

Copies of Data

3

Storage Overhead

~3x (before deduplication)

When to Use N+2

N+2 is designed for environments with a specific requirement to withstand more than one simultaneous failure. Common scenarios include ultra-critical workloads where even the brief exposure during a rebuild is unacceptable, or remote/edge sites where failed hardware cannot be replaced quickly. In these cases, the extra infrastructure cost of N+2 may be justified.

Per-Tier Redundancy

A failure only affects the tier where the failed drives reside. For example, in an N+2 configuration, if drives on Tier 1 fail on two nodes and a Tier 4 drive fails on a different node, the cluster remains fully operational, and no data is lost.

Configuring vSAN Redundancy Level

Redundancy level is typically configured during system installation.

Changing a System's Redundancy Levels

It is possible to upgrade an N+1 system to N+2 (provided the minimum node requirement is met). This transition involves a data rebalancing process.

Viewing Tier Redundancy Status

To check the current redundancy configuration and status of a vSAN tier:

  1. Navigate to Infrastructure > vSAN Tiers from the top menu.

  2. Double-click the desired tier to open its dashboard.

  3. Locate the Status card:

    • Redundancy — Displays the configured redundancy level (e.g., N+1 with 2 copies, N+2 with 3 copies).

    • Redundant checkbox — Indicates whether the tier is currently meeting its configured redundancy level. This will be unchecked if any nodes or tier drives are down.

Quick Comparison

Feature
N+1 (RF2)
N+2 (RF3)

Copies of data

2

3

Simultaneous failures tolerated

1

2

Minimum controller nodes

2

3

Recommended nodes

3

5

Storage overhead (before dedup)

~2x

~3x

Default

Yes

No


Document Information

  • Last Updated: 2026-03-03

  • VergeOS Version: 26.1.2