Local Node Tier 0 Metadata Redundancy (D+x)
How VergeOS mirrors Tier 0 metadata across a controller node's local drives (D+x) to match the system redundancy level, and how the drive count sets usable metadata capacity.
Overview
Tier 0 is the most critical storage tier in a VergeOS system. It holds metadata, and without metadata, data on all tiers becomes inaccessible. Tier 0 lives only on controller nodes.
Node-to-node redundancy (N+1 or N+2) keeps metadata copies across controller nodes. Inside each controller node, VergeOS also mirrors metadata across the node's local Tier 0 drives. This local mirroring (D+x) matches the system redundancy level: an N+1 system keeps two local copies (D+1), and an N+2 system keeps three (D+2) — but never more copies than the node has Tier 0 drives.
Local Copies and Usable Capacity by Drive Count
Local copies divide raw capacity:
Usable Tier 0 capacity ≈ total raw Tier 0 capacity ÷ number of local copies
The table below uses 1 TB drives for simplicity:
N+1
1
1 TB
1
1 TB
None
N+1
2
2 TB
2
1 TB
Full (D+1)
N+1
3
3 TB
2
1.5 TB
Full (D+1)
N+1
4
4 TB
2
2 TB
Full (D+1)
N+2
1
1 TB
1
1 TB
None
N+2
2
2 TB
2
1 TB
Partial (D+1)
N+2
3
3 TB
3
1 TB
Full (D+2)
N+2
4
4 TB
3
1.33 TB
Full (D+2)
For example, an N+2 system targets three local copies (D+2), but a controller node with only two Tier 0 drives can only provide two. Drives beyond the required copy count add usable capacity, not more copies. As a real-world example, a controller node with two 1.6 TB drives on an N+1 system provides ~1.6 TB of usable metadata capacity.
Sizing Recommendations
Install the same number of Tier 0 drives, of the same size, in each controller node.
For N+1 systems, install two Tier 0 drives per controller node for full local protection (D+1).
For N+2 systems, install three Tier 0 drives per controller node for full local protection (D+2).
For per-terabyte metadata sizing guidance, see the Node Sizing Guide.
When a Tier 0 Drive Fails
If a Tier 0 drive fails, the remaining drives continue to serve metadata without interruption. The tier then runs with reduced local protection until you replace the drive. While the drive is down, the Redundant checkbox on the tier's status card is cleared — see Viewing Tier Redundancy Status. Replace the failed drive as soon as possible.
Next Steps
Understanding vSAN Redundancy Levels — N+1 and N+2 node-to-node redundancy.
Storage Tiers in VergeOS vSAN — the full tier model, including Tier 0 hardware guidance.
Replacing a Defective or End-of-life Drive — the drive replacement procedure.
Node Sizing Guide — Tier 0 capacity and drive recommendations.