External Storage Integration
Guide to integrating external SAN, NAS, and iSCSI storage with VergeOS, covering Fibre Channel LUNs as vSAN tiers, NFS/CIFS remote volumes, and in-guest storage passthrough options.
Overview
While VergeOS is designed as a hyperconverged platform with its own vSAN storage, it can integrate with external storage systems in several ways. This guide explains your options for using external SAN, NAS, and iSCSI storage with VergeOS.
Integration Options
Option 1: Fibre Channel LUNs as vSAN Tier
Best for: Organizations with existing FC SAN investments
VergeOS can use Fibre Channel LUNs as storage within its vSAN tiers. Each node receives its own dedicated LUN(s)—VergeOS treats FC LUNs like local physical disks.
Key points:
LUNs must be unique per node (no shared LUNs between nodes)
Disable RAID on the SAN—VergeOS handles redundancy
FC HBAs required in at least two nodes
See Using Fibre Channel Storage with vSAN for details
Option 2: NFS/CIFS Remote Volumes (NAS)
Best for: VM exports, backups to external storage, legacy application data
VergeOS NAS service can mount remote NFS and CIFS shares, making external storage accessible to VMs and for backup purposes.
Use cases:
VM export destinations for backup
Accessing legacy file data during migrations
Integration with backup appliances
Configuration:
Navigate to NAS > Volumes
Create a new Remote Volume
Select NFS or CIFS protocol
Enter server address and share path
Configure authentication if required
See NAS Remote Volumes for detailed steps.
Option 3: In-Guest iSCSI/NFS (Passthrough)
Best for: Applications requiring direct SAN access, clustered applications
VMs can connect directly to external storage using in-guest iSCSI initiators or NFS clients, bypassing VergeOS storage entirely.
Use cases:
Microsoft Failover Clustering with shared storage
Oracle RAC
Applications requiring specific SAN features
Configuration:
Configure VM networking to reach the storage network
Install and configure iSCSI initiator or NFS client in the guest OS
Connect to storage targets as you would on physical servers
Comparison of Integration Methods
FC LUNs as vSAN tier
Yes
Yes
Yes
Leverage existing FC investment
NFS/CIFS Remote Volumes
No (NAS only)
No
Volume-level
Backups, exports, file access
In-Guest iSCSI/NFS
No
No
No
Direct SAN apps, clustering
Common Questions
Can VergeOS use a SAN as its only storage?
Technically yes, using FC LUNs as a vSAN tier. However, Tier 0 (metadata tier) still requires fast, low-latency storage—typically NVMe SSDs directly attached to nodes. Using external storage for Tier 0 is not recommended.
What about shared storage between nodes?
VergeOS vSAN does not use shared storage in the traditional sense. Each node contributes its own storage to the distributed vSAN. Data redundancy is achieved by storing copies across multiple nodes, not by multiple nodes accessing the same LUN.
Can I use my existing SAN for VM storage without vSAN?
Not directly. VergeOS VMs store their disks on vSAN. To use external storage:
Add the storage to a vSAN tier, or
Use in-guest iSCSI/NFS for specific applications, or
Use NAS remote volumes for file-level access
Does VergeOS support hardware RAID?
VergeOS requires disks in JBOD mode (no RAID). The vSAN handles data protection at the software level. If using a RAID controller, configure it for JBOD/HBA mode or individual disk presentation.
What about data migration from existing storage?
Options for migrating data to VergeOS:
VM migration: Import VMs from VMware, Hyper-V, or disk images
File migration: Mount external shares via NAS and copy data
Storage vMotion equivalent: Not available—migrate VMs instead
See VM Migration Overview for details.
Best Practices
When to Use External Storage Integration
Good reasons:
Existing SAN investment with available capacity
Compliance requirements for specific storage systems
Tiered storage architecture needs
Backup target integration
Consider alternatives when:
Building a new environment (local disks are simpler)
Cost is a concern (FC infrastructure is expensive)
Performance is critical (local NVMe often outperforms networked storage)
Performance Considerations
Network bandwidth: Ensure sufficient connectivity between nodes and storage
Latency: External storage adds network latency; measure impact on workloads
Queue depth: Monitor and tune HBA queue depths for FC configurations
Redundancy Planning
Remember that VergeOS provides redundancy at the vSAN level:
Data is stored on two nodes minimum
Disable RAID on external LUNs to avoid double redundancy overhead
Plan SAN-side redundancy for path failover, not data protection
Related Documentation