Standard operating procedure for scaling up vSAN storage capacity by adding drives to existing VergeOS nodes, including preparation, verification, execution, and post-scale-up checks.

This guide provides best practices for safely scaling up storage capacity in a VergeOS system by adding drives to existing nodes. It focuses on data security and system resilience through a methodical approach.

Overview

Scaling up a vSAN requires careful planning and execution to ensure minimal disruption to your services. This guide breaks down the process into main phases:

  1. Preparation - Steps to take before your scheduled maintenance window

  2. Pre-Scale Up Verification - Final checks immediately before beginning the scale up

  3. Scale Up Execution - The process of adding and configuring new storage

  4. Post-Scale Up Verification - Ensuring the scale up was successful

Environment-Specific Requirements

This guide covers general best practices. You may need to adapt these steps for your specific environment and requirements.

Prerequisites

  • Administrative access to VergeOS system

  • IPMI access to all nodes in the cluster

  • New storage drives properly tested and validated

  • Physical access to nodes for drive installation

Preparation Phase

Complete these steps well before your scheduled maintenance window:

System Readiness

Hardware Preparation

Documentation and Planning

Resource Verification

Pre-Scale Up Verification

Perform these checks on the day of scheduled maintenance, before beginning the scale up:

Current State Verification

Execution Phase

Adding New Storage

For detailed step-by-step instructions on performing the vSAN scale up, please refer to:

Scaling Up a vSAN

Key Process Overview

  1. Put the node in Maintenance Mode (if hot-swap not supported)

  2. Power down target node (if hot-swap not supported)

  3. Install new drives following manufacturer guidelines

  4. Power up node and verify drive detection

  5. Add drives to vSAN tier via VergeOS UI

  6. Monitor tier repair progress - this may take significant time

  1. Repeat for each storage node until complete

Post-Scale Up Verification

After the scale up completes, verify the system is operating correctly:

System Health Checks

Troubleshooting

Common Issues

vSAN tier remains yellow after extended time

  • Verify all new drives are properly seated and detected

  • Check for drive errors in logs

  • Ensure sufficient network bandwidth for repairs

  • Contact support if repairs stall

  • vSAN repairs may take hours, days, or more, depending on many factors like total data stored and drive speed

New drives not detected

  • Verify physical drive installation

  • Check disk controller configuration if applicable

  • Confirm drive compatibility with existing hardware

  • Review system logs for hardware detection issues

Performance degradation during repairs

  • VergeOS makes every effort to prioritize workload storage during repairs

  • Consider minimizing workloads during maintenance window to reduce any possible impact

  • Monitor system resources

Rollback Procedure

Next Steps

After successful scale up completion:

Last updated