VergeOS vSAN Scale Up Guide
Standard operating procedure for scaling up vSAN storage capacity by adding drives to existing VergeOS nodes, including preparation, verification, execution, and post-scale-up checks.
This guide provides best practices for safely scaling up storage capacity in a VergeOS system by adding drives to existing nodes. It focuses on data security and system resilience through a methodical approach.
Scaling Down vSAN Storage Requires Support
This guide covers adding drives to increase capacity. Removing drives to reduce vSAN capacity is not a self-service operation. Due to the complexity of safely redistributing data, drive removal must be coordinated with VergeOS Support. Open a support ticket to initiate a scale-down request.
Prerequisites
Administrative access to VergeOS system
IPMI access to all nodes in the cluster
New storage drives properly tested and validated
Physical access to nodes for drive installation
Preparation Phase
Complete these steps well before your scheduled maintenance window:
System Readiness
Hardware Preparation
Documentation and Planning
Resource Verification
Pre-Scale Up Verification
Perform these checks on the day of scheduled maintenance, before beginning the scale up:
Current State Verification
Execution Phase
Adding New Storage
For detailed step-by-step instructions on performing the vSAN scale up, please refer to:
Key Process Overview
Put the node in Maintenance Mode (if hot-swap not supported)
Power down target node (if hot-swap not supported)
Install new drives following manufacturer guidelines
Power up node and verify drive detection
Add drives to vSAN tier via VergeOS UI
Monitor tier repair progress - this may take significant time
Critical Wait Period
During the scale up process, the vSAN Tier will show a yellow status during the repair stage. It is essential to wait for the vSAN tier to return to a "green" healthy status before continuing to the next node.
Monitoring Progress
Monitor vSAN repair progress in the VergeOS UI under System -> vSAN. The process will show completion status and available capacity updates.
Repeat for each storage node until complete
Post-Scale Up Verification
After the scale up completes, verify the system is operating correctly:
System Health Checks
Troubleshooting
Common Issues
vSAN tier remains yellow after extended time
Verify all new drives are properly seated and detected
Check for drive errors in logs
Ensure sufficient network bandwidth for repairs
Contact support if repairs stall
vSAN repairs may take hours, days, or more, depending on many factors like total data stored and drive speed
New drives not detected
Verify physical drive installation
Check disk controller configuration if applicable
Confirm drive compatibility with existing hardware
Review system logs for hardware detection issues
Performance degradation during repairs
VergeOS makes every effort to prioritize workload storage during repairs
Consider minimizing workloads during maintenance window to reduce any possible impact
Monitor system resources
Rollback Procedure
Emergency Support
Should you have any issues with your VergeOS vSAN scale up, please contact our support team for immediate assistance.
Next Steps
After successful scale up completion:
Last updated
Was this helpful?