VergeOS Installation Guide
Standard operating procedure for an initial VergeOS installation, covering hardware preparation, network configuration, primary and secondary controller setup, and post-installation verification.
This guide provides standardized procedures and best practices for VergeOS Engineers and Administrators performing an initial system installation using the updated installer interface.
Prerequisites
Physical access to hardware nodes for installation
Network infrastructure configured and ready
IPMI/remote management access to all nodes
VergeOS license credentials
Estimated time: 4-8 hours depending on configuration complexity
Objective
Completing initial installation of Node1 and Node2+, the minimum required for system redundancy and production system support.
Preparation Phase
Complete these steps prior to scheduling installation:
Hardware Requirements
Installation Media and Documentation
Create install media per VergeOS documentation
Test boot media to verify functionality
Document and Create all network requirements
System Access and Configuration
Verify IPMI access to all nodes
Review BIOS settings requirements
Proper Boot Method Selected (Legacy/Dual/UEFI) UEFI required if all drives are NVMe
Hardware assisted virtualization enabled
Hyperthreading enabled
All processor cores enabled
Clocks set correctly (All Nodes within seconds)
Planning Decisions
Review the entire procedure described here
Prepare information required to complete the entire process
Decide RAM reservation preference: More Usable Memory OR More enforcement of N+1 HA
Plan installation timeline and communication to stakeholders
Pre-Installation Phase
Perform these checks within 24 hours prior to scheduled installation:
Current State Verification
Verify Current State
All hardware physically installed and powered
All network cables pass a "tug test"
Switch configurations complete and tested
Current running network configuration checked and a "write mem" completed
IPMI accessible on all nodes
Required IPs are available and open
Jumbo frames (MTU 9216+) configured on switches
Hardware Final Check
All drives showing in BIOS
All NICs showing in BIOS
Confirm MACs vs records
Time and date correct in BIOS
Virtualization settings enabled
Network Final Check
Core network switches responding
External network switches responding
No conflicting DHCP servers (if using DHCP)
Documentation available for troubleshooting
Execution Phase
Primary Controller Installation
The actual installation process following the installer order:
Boot from USB installer
Select "Standard Install"
Select "Controller"
Select "New Install"
System Configuration
NTP Configuration:
Enter space-delimited list of NTP servers, or leave default
Date/Time Configuration:
Carefully confirm current date
Very carefully confirm current time (Node 1 controls NTP for the system)
System Identification:
Enter your System name. (This may be changed after installation)
Admin Account Configuration
Enter your Administrator username, or leave default
Enter the password for your administrator account (it should be generated and stored in your password repository)
Set the administrator account email address (optional but advised)
Network Interface Configuration
Core Network Interfaces:
Select Core1 Network Interface
Configure Core1 Interface Name, MTU, Core (Leave "Yes"), and VLAN as required
Select Core2 Network Interface
Configure Core2 Interface Name, MTU, Core (Leave "Yes"), and VLAN as required
External Network Interface:
Select External Network Interface
Configure External Network Name, MTU (Generally 1500), Core (Change to "No").
Configure External VLAN (if required)
Set External IP (CIDR format)
Set External Gateway
Set External DNS servers
License Configuration
Select License Server (Production or Trial/NFR)
Enter License User credentials
Enter License Password (store securely in password repository)
Storage Configuration
vSAN Encryption:
Choose vSAN Encryption setting (Yes/No)
Document encryption key, if enabled (store securely in password repository)
Create USB Encryption disk (highly recommended if using vSAN encryption)
vSAN Disk Selection & Tier Assignment:
Select vSAN disks for installation
Assign disks to appropriate storage tiers (as planned during installation prep)
Swap Configuration:
Configure swap assignment as required
After the Installer is Finished, remove the USB media
Reboot
Primary Node Verification
System boots to 'blue' screen at console
UI accessible at configured IP address
All status indicators green in UI
vSAN mounted and healthy
Secondary Controller Installation
Boot secondary node from USB installer
Select "Controller"
Select "No" for new install
Enter admin credentials from primary controller
Confirm network auto-detection (STOP if any detected IP or Interface is not as-expected!)
Match encryption settings from primary
Match drive Tier assignments from primary
Secondary Node Verification
System boots to 'blue' screen at console
Node2 visible in primary UI
All status indicators green
vSAN status green across both nodes
Post-Installation Verification
After the installation completes, verify the system is operating correctly:
System Health Checks
All Dashboard indicators green
No unexpected alerts or warnings in Dashboard Logs
All Nodes showing correct version
All Nodes in "Running" state (check each individual node)
No pending Node reboots
vSAN health green across all Tiers
Core fabric connectivity verified
External network connectivity verified
System Configuration Validation
Default VM Storage Tier Set
Cluster Target Max RAM percentage configured
Site Syncs configured (if required)
System Activated and up to date
SMTP Server setup (highly recommended)
Admin user email notifications configured
Final Testing
Test VM creation and basic operations
Verify network connectivity from test VM
Confirm snapshot functionality
Test system backup/restore if applicable
Troubleshooting
Common Issues
Boot Issues:
Verify BIOS boot settings match installation media type
Check USB media functionality on known working system
Confirm hardware compatibility with VergeOS
Network Configuration Issues:
Verify VLAN configurations match network design
Check physical cable connections and switch configurations
Confirm IP addressing doesn't conflict with existing infrastructure
Storage Configuration Issues:
Verify disk controller is in JBOD/IT mode
Check disk visibility in BIOS
Confirm storage tier assignments match planning documentation
Secondary Node Join Issues:
Verify network connectivity between nodes
Check admin credentials are correct
Confirm primary node is fully operational before adding secondary
Next Steps
After successful installation completion:
Schedule initial system backup
Configure monitoring and alerting
Update network documentation with final configuration
Plan tenant creation and resource allocation
Schedule administrator training if needed
Document final system configuration for operations team
Emergency Support
Should you have any issues with your VergeOS installation, please contact our support team for immediate assistance.
Last updated
Was this helpful?