Switch configuration guide
Switch port configuration for VergeOS covering core fabric access ports with jumbo frames, external VLAN trunk ports with LACP, and verification for Cisco, Dell, and HPE/Aruba switches.
Overview
This guide covers switch port configuration for VergeOS node deployments. You'll configure two network types: Core Fabric (internal System/vSAN Storage) and External (workload connectivity). Proper switch configuration ensures optimal performance, security, and reliability.
Target Audience: Infrastructure and network administrators deploying VergeOS Systems
What You'll Learn
Configure isolated VLAN access ports for core fabric with jumbo frames
Set up VLAN trunk ports with LACP for external networks
Verify switch configuration and troubleshoot common issues
Common questions answered:
What switch configuration does VergeOS require?
How do I configure jumbo frames for storage traffic?
Should I use LACP or active-backup for external networks?
How do I isolate core fabric from external traffic?
Quick Reference
Core Fabric
Access port, Isolated VLANs, MTU 9216, No STP
Isolate cluster/storage traffic
External
Trunk port, Multiple VLANs, Active/Backup bonding, LACP (optional)
Workload connectivity with redundancy
Understanding Network Types
Core Fabric Network
Private high-speed network for VergeOS cluster operations carrying vSAN storage, cluster coordination, and VM migration traffic.
Requirements:
Dedicated VLANs (isolated from ALL OTHER networks)
Jumbo frames (MTU 9216) for storage efficiency
Access port configuration (single untagged VLAN per core network)
10Gbps or higher recommended
External Networks
Networks connecting VMs and workloads to users, internet, and other infrastructure.
Requirements:
Multiple VLANs for tenant/workload separation
LACP bonding for redundancy (or active-backup)
Trunk port configuration
Standard MTU 1500 (or 9000 if workloads require)
Configuration Steps
1. Prepare Switch
Access the switch via console/SSH and enter configuration mode.
Enter configuration mode:
Create VLANs:
Enable jumbo frames globally:
Enter configuration mode:
Create VLANs:
Enable jumbo frames globally:
Enter configuration mode:
Create VLANs:
Enable jumbo frames globally:
MTU Size Requirement
VergeOS requires MTU 9216 on switch ports to accommodate the 9000-byte payload plus VLAN tags, headers, and overhead for Tenants. Setting MTU below 9216 will cause packet fragmentation and degrade storage performance.
2. Configure Core Fabric Ports
Configure each port connecting to node core fabric NICs as an access port with jumbo frames.
Configuration (per core fabric port):
Configuration (per core fabric port):
Configuration (per core fabric port):
**Repeat for all nodes:**
Node1: Core fabric ports 1-2
Node2: Core fabric ports 1-2
Node3: Core fabric ports 1-2
Key settings:
Mode: access (untagged, single VLAN)
VLAN: 900/901 (core fabric isolation)
MTU: 9216 (jumbo frames for storage)
Spanning Tree: Disabled (not needed for core-fabric links)
3. Configure External Network Ports (LACP)
For external networks, configure LACP port-channels for redundancy and bandwidth aggregation.
Create port-channel:
Add member ports:
Create port-channel (LAG):
Add member ports:
Create LAG (port-channel):
Add member ports:
**Repeat for additional nodes** (Po2, Po3, etc.)
Key settings:
Mode: trunk (multiple tagged VLANs)
Allowed VLANs: 10,20 (only workload and VergeOS management VLANs)
LACP mode: active (initiates negotiation)
4. Configure External Ports (Active-Backup Alternative)
If LACP isn't available or preferred, configure individual trunk ports without bonding.
Verification
Check Core Fabric Configuration
Expected results:
Mode: access
VLAN: 900
MTU: 9216
Expected results:
Mode: access
Access VLAN: 900
MTU: 9216
Expected results:
Mode: access
Access VLAN: 900
MTU: 9216
Check External Network Configuration (LACP)
Expected results:
Port-channel status: SU (in use)
Member ports: (P) bundled
Allowed VLANs: 10,20
Native VLAN: 99
Expected results:
Port-channel status: up
Member ports: Active
Allowed VLANs: 10,20
LACP mode: active
Expected results:
LAG status: up
Member ports: Active
Allowed VLANs: 10,20
LACP mode: active
Test Connectivity After Node Connection
Verify links are up:
Check LACP negotiation:
Verify links are up:
Check LACP negotiation:
Verify links are up:
Check LACP negotiation:
Test jumbo frames from VergeOS node:
Troubleshooting
No link on core ports
Port shutdown
no shutdown command
Slow storage performance
Jumbo frames disabled
Set MTU 9000
Node can't join cluster
Wrong VLAN
Assign port to VLAN 100
LACP not forming
Mode mismatch
Set mode active on both ends
VLANs not working
Not in allowed list
Add VLANs to trunk
Port-channel suspended
Config mismatch on members
Ensure identical config
Get help:
Review switch vendor documentation
Contact VergeOS support with
show running-configandshow interfaces statusoutput
Configuration Summary
Core Fabric Ports
Mode: Access (untagged)
VLAN: Dedicated (e.g., 900,901)
MTU: 9216 (jumbo frames)
Speed: 10Gbps+ recommended
External Network Ports
Mode: Trunk (802.1Q tagged)
VLANs: Multiple allowed (e.g., 10,20,30)
Bonding: LACP active mode (or active-backup)
Save Configuration
Next Steps
Configure VergeOS Network Bonds - Set up bonding on VergeOS side
Create VergeOS Networks - Define internal and external networks
Verify Connectivity - Test inter-node and external routing
Additional Resources
VergeOS Networking Architecture Overview
Network Bonding Best Practices
Switch vendor configuration guides
VergeOS Support: support@verge.io | https://docs.verge.io
Last Updated: January 2025 | VergeOS v4.x | Applies to: Cisco IOS/IOS-XE, Dell OS10, HPE/Aruba
Last updated