Switch configuration guide

Switch port configuration for VergeOS covering core fabric access ports with jumbo frames, external VLAN trunk ports with LACP, and verification for Cisco, Dell, and HPE/Aruba switches.

Overview

This guide covers switch port configuration for VergeOS node deployments. You'll configure two network types: Core Fabric (internal System/vSAN Storage) and External (workload connectivity). Proper switch configuration ensures optimal performance, security, and reliability.

Target Audience: Infrastructure and network administrators deploying VergeOS Systems

What You'll Learn

  • Configure isolated VLAN access ports for core fabric with jumbo frames

  • Set up VLAN trunk ports with LACP for external networks

  • Verify switch configuration and troubleshoot common issues

Common questions answered:

  • What switch configuration does VergeOS require?

  • How do I configure jumbo frames for storage traffic?

  • Should I use LACP or active-backup for external networks?

  • How do I isolate core fabric from external traffic?

Quick Reference

Network Type
Configuration
Purpose

Core Fabric

Access port, Isolated VLANs, MTU 9216, No STP

Isolate cluster/storage traffic

External

Trunk port, Multiple VLANs, Active/Backup bonding, LACP (optional)

Workload connectivity with redundancy


Understanding Network Types

Core Fabric Network

Private high-speed network for VergeOS cluster operations carrying vSAN storage, cluster coordination, and VM migration traffic.

Requirements:

  • Dedicated VLANs (isolated from ALL OTHER networks)

  • Jumbo frames (MTU 9216) for storage efficiency

  • Access port configuration (single untagged VLAN per core network)

  • 10Gbps or higher recommended

External Networks

Networks connecting VMs and workloads to users, internet, and other infrastructure.

Requirements:

  • Multiple VLANs for tenant/workload separation

  • LACP bonding for redundancy (or active-backup)

  • Trunk port configuration

  • Standard MTU 1500 (or 9000 if workloads require)


Configuration Steps

1. Prepare Switch

Access the switch via console/SSH and enter configuration mode.

Enter configuration mode:

Create VLANs:

Enable jumbo frames globally:

Enter configuration mode:

Create VLANs:

Enable jumbo frames globally:

Enter configuration mode:

Create VLANs:

Enable jumbo frames globally:

2. Configure Core Fabric Ports

Configure each port connecting to node core fabric NICs as an access port with jumbo frames.

Configuration (per core fabric port):

Configuration (per core fabric port):

Configuration (per core fabric port):

**Repeat for all nodes:**

  • Node1: Core fabric ports 1-2

  • Node2: Core fabric ports 1-2

  • Node3: Core fabric ports 1-2

Key settings:

  • Mode: access (untagged, single VLAN)

  • VLAN: 900/901 (core fabric isolation)

  • MTU: 9216 (jumbo frames for storage)

  • Spanning Tree: Disabled (not needed for core-fabric links)

3. Configure External Network Ports (LACP)

For external networks, configure LACP port-channels for redundancy and bandwidth aggregation.

Create port-channel:

Add member ports:

Create port-channel (LAG):

Add member ports:

Create LAG (port-channel):

Add member ports:

**Repeat for additional nodes** (Po2, Po3, etc.)

Key settings:

  • Mode: trunk (multiple tagged VLANs)

  • Allowed VLANs: 10,20 (only workload and VergeOS management VLANs)

  • LACP mode: active (initiates negotiation)

4. Configure External Ports (Active-Backup Alternative)

If LACP isn't available or preferred, configure individual trunk ports without bonding.

VergeOS can handle failover in software using active-backup bonding if LACP is not available.


Verification

Check Core Fabric Configuration

Expected results:

  • Mode: access

  • VLAN: 900

  • MTU: 9216

Expected results:

  • Mode: access

  • Access VLAN: 900

  • MTU: 9216

Expected results:

  • Mode: access

  • Access VLAN: 900

  • MTU: 9216

Check External Network Configuration (LACP)

Expected results:

  • Port-channel status: SU (in use)

  • Member ports: (P) bundled

  • Allowed VLANs: 10,20

  • Native VLAN: 99

Expected results:

  • Port-channel status: up

  • Member ports: Active

  • Allowed VLANs: 10,20

  • LACP mode: active

Expected results:

  • LAG status: up

  • Member ports: Active

  • Allowed VLANs: 10,20

  • LACP mode: active

Test Connectivity After Node Connection

Verify links are up:

Check LACP negotiation:

Verify links are up:

Check LACP negotiation:

Verify links are up:

Check LACP negotiation:

Test jumbo frames from VergeOS node:


Troubleshooting

Issue
Cause
Fix

No link on core ports

Port shutdown

no shutdown command

Slow storage performance

Jumbo frames disabled

Set MTU 9000

Node can't join cluster

Wrong VLAN

Assign port to VLAN 100

LACP not forming

Mode mismatch

Set mode active on both ends

VLANs not working

Not in allowed list

Add VLANs to trunk

Port-channel suspended

Config mismatch on members

Ensure identical config

Get help:

  • Review switch vendor documentation

  • Contact VergeOS support with show running-config and show interfaces status output


Configuration Summary

Core Fabric Ports

  • Mode: Access (untagged)

  • VLAN: Dedicated (e.g., 900,901)

  • MTU: 9216 (jumbo frames)

  • Speed: 10Gbps+ recommended

External Network Ports

  • Mode: Trunk (802.1Q tagged)

  • VLANs: Multiple allowed (e.g., 10,20,30)

  • Bonding: LACP active mode (or active-backup)

Save Configuration


Next Steps

  1. Configure VergeOS Network Bonds - Set up bonding on VergeOS side

  2. Create VergeOS Networks - Define internal and external networks

  3. Verify Connectivity - Test inter-node and external routing

Additional Resources

  • VergeOS Networking Architecture Overview

  • Network Bonding Best Practices

  • Switch vendor configuration guides

VergeOS Support: support@verge.io | https://docs.verge.io


Last Updated: January 2025 | VergeOS v4.x | Applies to: Cisco IOS/IOS-XE, Dell OS10, HPE/Aruba

Last updated

Was this helpful?