The VergeOS Isolation Model
VergeOS multi-tenancy is built on architectural isolation — not just policy-based separation. Every tenant is a fully encapsulated Virtual Data Center (VDC) with its own networking stack, exclusive storage volumes, and independent administrative boundary. This stands in contrast to platforms that rely on VLANs, resource pools, or RBAC rules to separate tenants within a shared management plane.
The isolation model rests on four pillars:
Network Encapsulation
Network encapsulation is the foundation of tenant isolation. When a tenant is created, VergeOS automatically provisions a virtual network that aggregates and encapsulates all of that tenant's traffic. From the tenant's perspective, this is their physical network — they cannot see or interact with any other tenant's traffic.
How It Works
Each tenant receives its own DMZ network that serves as the routing backbone for all networks within the tenant
Tenant traffic is encapsulated at Layer 2 and Layer 3, preventing cross-tenant communication at the network level
The encapsulated network allows tenant nodes to communicate securely even when running on different physical hosts
Tenants can create virtually unlimited internal networks within their own environment
Why This Matters
Unlike VLAN-based segmentation — where a misconfigured VLAN tag or a compromised switch could expose traffic between tenants — VergeOS network encapsulation provides zero-trust network isolation by default. A tenant cannot reach another tenant's network even if they share the same physical infrastructure.
Dedicated Storage Volumes
Each tenant receives dedicated storage volumes within the vSAN, presented to the tenant as if it had its own storage system. Isolation is enforced logically through container filesystem boundaries — a tenant cannot see or access another tenant's data — while the underlying vSAN deduplicates blocks across the whole cluster for efficiency.
Key characteristics:
Per-tenant provisioning — Storage is provisioned per tier (NVMe, SSD, HDD) with specific capacity allocations
Independent deduplication — Each tenant's dedup stats reflect only its own data. Deduplication operates at the vSAN block level across the entire system; tenant-visible metrics show per-tenant savings only
Thin provisioning — Tenant storage is thin-provisioned. A 4 TB VM drive that contains only 200 GB of data consumes ~200 GB of vSAN capacity (minus dedup savings)
Encryption support — vSAN encryption (AES-256, configured at install) applies to all data including tenant volumes
Independent User Management
Each tenant manages its own user accounts and authentication independently. Three authentication models are available:
Local users
Tenant admin creates and manages user accounts directly within the tenant UI
Small tenants, standalone environments
Parent VergeOS (via OIDC)
Tenant authenticates via an OIDC application defined on the parent VergeOS system, so tenant logins are backed by the parent's user directory
Managed service providers who control tenant access centrally
Third-party IdP (via OIDC)
Tenant integrates with an external identity provider (Okta, Azure AD/Entra, Google Cloud Identity, etc.) via OIDC
Enterprise tenants with existing identity infrastructure
The OIDC integration is configured per tenant during creation or modification. When an OIDC application is selected, the tenant uses the external identity provider for authentication while maintaining local authorization (permissions and roles).
Layer 2 Pass-Through to Tenants
In some scenarios, a tenant needs direct Layer 2 access to a physical VLAN — for example, to connect to a dedicated WAN link, a physical storage network, or legacy applications requiring L2 adjacency.
VergeOS provides Tenant Layer 2 Networks (recent VergeOS versions) for streamlined VLAN pass-through:
How It Works
The host administrator navigates to Tenants → [Tenant] → Layer2 Networks → New
Selects the external Layer 2 network (VLAN) to pass through
Enables the pass-through
VergeOS automatically creates three components inside the tenant:
A NIC interface on the tenant node connected to the VLAN
A Physical network (backend infrastructure)
An External network that tenant VMs can attach to
Verification Checklist
Host
Layer 2 network appears in tenant's Layer2 Networks list, Enabled = ON
Tenant
External and Physical networks appear in tenant's Networks list
Infrastructure
Physical switch ports carry the VLAN to the correct nodes
Connectivity
Test VM on the tenant's External network can reach devices on the VLAN
Important Restrictions
Reserved VLANs
VLANs 1, 100, 101, and 102 are reserved for VergeOS internal traffic and cannot be used for Layer 2 pass-through.
Do Not Tag the Tenant External Network
The External network created inside the tenant is already tagged for the correct VLAN. Do not add a VLAN tag to the tenant-side External network — this is a common misconfiguration that will break connectivity.
Removal Procedure
Removing a Tenant Layer 2 Network requires a specific order:
Disable the Layer 2 network from the host side
Delete the Layer 2 network from the host side (NIC is automatically removed)
Inside the tenant: delete the External network first, then the Physical network
Always delete the External network before the Physical network inside the tenant. The External network references the Physical network as its interface, so reversing the order will produce an error.
Micro-Segmentation Within Tenants
Each tenant can implement its own micro-segmentation strategy using the same networking tools available at the host level:
Internal networks — Each internal network is a default-secure, isolated segment. No traffic flows in or out until explicit rules are added.
Network rules — Granular firewall rules (Accept, Drop, Reject), NAT/PAT, and static routes per network
Network aliases — Group IP addresses or CIDR ranges for simplified policy management
Port mirroring — Replicate a network's traffic to a VM NIC for analysis
This enables zero-trust principles within each tenant — workloads are isolated by default and communicate only through explicitly permitted paths.
Resource Guarantees
Tenant resource allocation is enforced at the platform level:
CPU and RAM — Cores and RAM assigned to tenant nodes are dedicated allocations; the host system accounts for tenant node resources in its scheduling
Storage — Provisioned storage per tier defines the tenant's capacity. While provisioned storage is not a hard limit, log alerts are triggered when a tenant approaches its threshold
Network bandwidth — Rate limiting can be applied per network rule for traffic shaping
Tenant Monitoring from the Parent
The host (parent) system retains full visibility into tenant operations without violating tenant isolation.
All-Tenants Dashboard
The All-Tenants Dashboard provides an overview of all tenants with:
Status indicators — Count of powered-on tenants and tenant nodes
Top usage lists — CPU, RAM, storage, and network usage ranked by tenant
Quick links — Click any tenant to drill into its individual dashboard
Individual Tenant Dashboard
Each tenant's dashboard shows:
CPU, RAM, and storage usage in 5-minute interval graphs
5-second heartbeat statistics for real-time monitoring
Log entries with errors highlighted in red
Storage metrics — Used, Provisioned, and Allocated values
Usage Reports for Billing
VergeOS stores usage statistics per tenant to support 95th percentile billing:
Navigate to the tenant dashboard → History
Select a filter period (month, custom range)
Click Apply to generate graphs showing Average, Maximum, and 95th percentile
Export to CSV for billing integration
Alternatively, configure a Subscription (System → Subscriptions → New) with:
Target Type: Tenants Dashboard
Type: Scheduled
Profile: Tenants Usage
This delivers automated usage reports via email on your configured schedule.
Snapshot Exposure
When the Expose System Snapshots option is enabled on a tenant, the tenant can browse the host's available snapshots and self-serve download their own tenant snapshot from the provider's snapshot timestamps. This gives tenants the ability to restore their own systems without requiring host administrator intervention.
Audit and Alerting
Subscriptions can trigger email alerts for tenant status errors, warnings, or threshold breaches
Scheduled reports can deliver daily/weekly dashboard summaries to administrators
The API can export tenant usage data to external billing or monitoring systems
Tenant Snapshots and Restores
Each tenant can be independently snapshotted and restored:
Per-tenant snapshots — The host can take snapshots of individual tenants without affecting other tenants
Tenant-controlled snapshots — Tenants can manage their own snapshot schedules and retention policies within their VDC
Granular restore — Restore an entire tenant, individual VMs, or specific data from any snapshot point
DR replication — Tenant snapshots can be replicated to remote sites via site sync, with per-tenant DR policies
Best Practices
Default to Encapsulation
Use VergeOS's built-in network encapsulation for all tenants. Only configure Layer 2 pass-through when there is a specific requirement for direct VLAN access.
Document VLAN Assignments
Maintain clear documentation of which VLANs are passed to which tenants, including VLAN IDs, purposes, and switch port configurations.
Least-Privilege Networking
Within each tenant, start with default-secure internal networks and open access only through explicit firewall rules. Follow zero-trust principles.
Monitor Storage Thresholds
Configure subscriptions to alert on tenant storage approaching provisioned limits. Thin provisioning means allocated can far exceed used — monitor "used" to track actual consumption.
Use OIDC for Enterprise Tenants
For enterprise tenants with existing identity infrastructure, configure OIDC integration rather than managing local user accounts within each tenant.
L2 Removal Order
When removing Layer 2 pass-through, always disable and delete from the host first, then clean up External before Physical networks inside the tenant.