The VergeOS Storage Tier Model
VergeOS vSAN organizes physical storage into 5 workload tiers (1–5) plus a dedicated metadata tier (Tier 0), each designed for a specific class of workload or data type. This tiered architecture allows organizations to balance performance, capacity, and cost by provisioning VM virtual disks on the most appropriate tier for their workload profile.
Tier 0 — Metadata
vSAN filesystem index and per-tier device maps. Required on controller nodes. Not a cache — exclusively metadata.
Tiers 1–3 — Performance
NVMe and SSD tiers for write-intensive, mixed, and read-optimized workloads respectively.
Tiers 4–5 — Capacity
HDD tiers for file servers, backup targets, compliance archives, and cold storage.
Unlike storage platforms that use a single pool with background data movement, VergeOS gives administrators explicit control over where data lives. You choose the tier when you provision a VM disk, and the data stays on that tier for the life of the virtual disk.
Tier Specifications
The following table summarizes each tier's hardware type, purpose, and typical use cases:
0
High-endurance NVMe
vSAN metadata
Filesystem index, per-tier device maps — required on controller nodes
1
High-endurance NVMe SSDs
Write-intensive workloads
High-performance databases, transaction logs, write-heavy apps
2
Mid-range SSDs
Mixed read/write workloads
General-purpose VMs, mixed application workloads, dev/test
3
Read-optimized SSDs
Read-intensive workloads
Content delivery, application repositories, reference data
4
High-capacity HDDs
Bulk capacity
File servers, backup targets, infrequently accessed data
5
Archival-grade HDDs
Cold storage / archive
Compliance archives, long-term retention, regulatory data
Tier 0: The Metadata Tier
Tier 0 deserves special attention because it is fundamentally different from the workload tiers. It stores only vSAN metadata — the filesystem index and the per-tier device maps from which block placement is derived. There is no central table tracking block locations or reference counts: placement is computed from each block's content hash against the device maps, and reference counts are rebuilt by the vSAN Walk.
Sizing guideline: Allocate approximately 5 GB of Tier 0 capacity per 1 TB of usable storage (minimum) or 10 GB per 1 TB (recommended) across your workload tiers. Use enterprise NVMe drives rated for 3 DWPD or equivalent (i.e. TBW). Always maintain at least 30% free space on Tier 0 to avoid metadata pressure.
Hardware requirements: Use enterprise-grade NVMe drives with a minimum of 3 DWPD (Drive Writes Per Day) endurance. Consumer NVMe drives are not supported for Tier 0 in production environments.
Workload Tiers (1–5)
Tiers 1 through 5 store actual VM data. Not every deployment needs all five workload tiers — many production environments use just two or three. The tier numbers are a ranking system: lower numbers indicate higher performance (and typically higher cost per GB), while higher numbers indicate higher capacity (at lower cost per GB).
Common deployment patterns:
All-flash: Tier 0 (metadata) + Tier 1 or 2 (all VM workloads)
Hybrid: Tier 0 (metadata) + Tier 2 (performance VMs) + Tier 4 (file servers, backups)
Multi-tier: Tier 0 (metadata) + Tier 1 (databases) + Tier 2 (general VMs) + Tier 4 (file shares) + Tier 5 (archive)
Preferred Tier Behavior
When creating or modifying a VM virtual disk, you set a Preferred Tier. Most deployments leave this at the system default, which is configurable under System > System Settings > Default VM Drive Tier. If the specified tier does not exist in the cluster:
Higher tier requested than available: The system selects the next higher (slower) tier. For example, requesting Tier 3 in a system with Tier 1 and Tier 4 results in placement on Tier 4.
Lower tier requested than available: The system selects the next lower (faster) tier. For example, requesting Tier 3 in a system with Tier 1 and Tier 2 results in placement on Tier 2.
This fallback behavior ensures VMs can always be provisioned, even if the exact requested tier is not present.
No Automatic Tiering
This is one of the most important concepts to understand about VergeOS storage:
Critical Concept: No Automatic Data Movement
VergeOS does NOT perform automatic hot/cold tiering based on access patterns. There is no policy-driven data movement. Data stays on its provisioned tier unless an administrator changes the disk's preferred tier — which triggers a live, online background migration with no downtime. Tier assignment is an administrative decision.
This design is intentional and offers several advantages:
Predictable performance — Workloads get consistent I/O characteristics because their data never migrates to slower media unexpectedly
Simple capacity planning — Each tier's capacity is consumed only by explicitly provisioned workloads
No background overhead — No tiering engine consuming CPU, memory, or I/O bandwidth to analyze and move data
Clear cost modeling — Storage costs map directly to provisioned tiers
To change a workload's tier placement, an administrator must manually move the VM's virtual disk to a different tier. This is a deliberate operational decision, not an automated process.
Drive Assignment Rules
Properly assigning physical drives to tiers is essential for a healthy vSAN. Follow these rules when configuring storage:
Rule 1: Controller Nodes Need Tier 0
Controller nodes must have at least one Tier 0 drive. Tier 0 holds the vSAN filesystem index and per-tier device maps (metadata), which are managed by the controller nodes. Scale-out and storage-only nodes contribute workload tiers (1–5) but do not host Tier 0; Tier 0 lives only on controller nodes (Nodes 1–2 for N+1, Nodes 1–3 for N+2).
Tier 0 is mandatory — the vSAN stores its filesystem index and device maps there, so the vSAN cannot mount or operate without it. This is why the controller nodes must have Tier 0 drives in place before any workload tier can be used; a system has no "no Tier 0" running state to cope with.
Rule 2: Consistent Drives Within a Tier
All drives within a tier should be of similar type, capacity, and performance. If you add a drive of a different size to an existing tier, the tier will only be able to use the capacity of the smallest drive in the tier. Mixing NVMe and SATA drives in the same tier is not recommended.
Rule 3: Equal Drive Counts Across Nodes
For balanced data distribution and optimal performance, each storage node should have the same number of drives per tier. For example, if Node 1 has two Tier 2 drives, Node 2 should also have two Tier 2 drives of the same type and capacity.
Rule 4: Cross-Node Distribution Per Tier
Each tier spans all storage-participating nodes. Block distribution, redundancy copies, and I/O load balancing operate independently within each tier. This means:
A failure on Tier 4 drives does not impact Tier 1 or Tier 2
A failure on one tier does not affect redundancy on other tiers — each tier's redundancy is tracked independently. The cluster-wide redundancy level (N+1 or N+2) applies uniformly to all tiers.
Capacity and performance scale independently per tier
Scaling Storage
vSAN supports two scaling approaches, and each tier can be scaled independently:
Vertical Scaling (Scale Up)
Add more drives to existing nodes within a tier. This increases the capacity and aggregate throughput of that tier without adding new hardware.
Key requirements for scaling up:
Ensure the vSAN has at least 30% free capacity before adding drives (unless you are doubling the drive count)
New drives must match the type, capacity, and performance of existing drives in the tier
Add the same number of drives to each storage node to maintain balanced distribution
Take a system snapshot before beginning the scale-up process
Follow the vSAN Scale Up SOP for the complete procedure
Horizontal Scaling (Scale Out)
Add new nodes to the cluster. This increases capacity, compute resources, and aggregate I/O bandwidth simultaneously.
Key requirements for scaling out:
New nodes should have the same drive configuration as existing nodes for each tier
Network connectivity (Core Fabric) must be verified before adding the node
The new node is installed via USB and joins the existing cluster
After joining, vSAN automatically begins distributing data to the new node
Follow the vSAN Scale Out Guide for the complete procedure
Scaling Decision Matrix
Capacity increase
Per-tier only
All tiers + compute
Performance increase
Moderate (more spindles)
Significant (more nodes)
Compute resources
No change
Additional CPU + RAM
Failure domain
No change
Better distribution
Complexity
Lower
Higher
Typical use case
Running low on one tier
Need more overall capacity
Capacity Planning
Proactive capacity planning prevents performance degradation and ensures the vSAN operates within healthy parameters.
Recommended Free Space Thresholds
Tier 0
30%+
Metadata pressure impacts all I/O operations system-wide
Tiers 1–3
20–30%
Performance tiers need headroom for dedup operations and writes
Tiers 4–5
15–20%
Capacity tiers need headroom for snapshot retention
Key Metrics to Monitor
Track these metrics in the VergeOS storage dashboard to maintain healthy tier operations:
Capacity utilization per tier — Trend over time to predict when scaling is needed
I/O performance (IOPS and latency) — Identify tiers that may be bottlenecking workloads
Deduplication ratios — Understand effective vs. raw capacity savings per tier
Drive error rates — Early warning for impending drive failures
Rebuild status — Monitor self-healing progress after drive replacements
RAM Requirements
vSAN requires dedicated RAM for storage operations. Plan for 1 GB of RAM per 1 TB of raw storage (minimum) or 1.5 GB per 1 TB (recommended) on each storage-participating node. This RAM is consumed by the VergeOS host and is not available to VMs.
Integration with Snapshots and Clones
Storage tiers interact with vSAN's snapshot and clone capabilities in important ways:
Snapshots are tier-aware — A snapshot of a VM with a Tier 2 disk references blocks on Tier 2. The snapshot metadata is recorded on Tier 0, but the data blocks remain on their original tier.
Clones reference the same tier — When you clone a VM, the clone initially references the same data blocks on the same tier. New writes from the clone consume space on the same tier as the original.
Deduplication operates per tier — The hash-based dedup engine works across all data within each tier, providing space savings that are tracked and reported independently per tier.
Replication is bandwidth-optimized — During site-sync replication, only unique blocks are transmitted (dedup-aware), and compression is applied to the transfer stream to reduce WAN bandwidth.
Key Takeaways
Tier model
5 workload tiers (1–5) plus a dedicated metadata tier (Tier 0); Tiers 1–3 = performance (NVMe/SSD); Tiers 4–5 = capacity (HDD)
No automatic tiering
Data stays on the provisioned tier — no hot/cold migration engine
Preferred tier
Set per VM disk; falls back to nearest available tier if requested tier is absent
Drive rules
Similar drives per tier, equal counts across nodes, controller nodes need Tier 0
Scaling
Vertical (add drives) or horizontal (add nodes) — each tier scales independently
Capacity planning
30%+ free on Tier 0, 20–30% on workload tiers, 1 GB RAM per 1 TB raw storage
Snapshot integration
Snapshots are tier-aware; dedup operates per tier; replication is bandwidth-optimized
Next Steps
With an understanding of how storage tiers are organized and managed, the next topic covers file-level storage access: NAS Service & Shares
Last updated
Was this helpful?