> For the complete documentation index, see [llms.txt](https://docs.verge.io/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://docs.verge.io/learn-the-platform/module-2-sizing-and-design/01-hardware-requirements.md).

# Hardware Requirements

Minimum and recommended hardware specifications for VergeOS controller nodes, storage nodes, and compute-only nodes.

## Overview

Sizing a VergeOS deployment starts with understanding the hardware requirements for each node role. Because VergeOS is a complete infrastructure operating system -- not a collection of separate products -- its base overhead is remarkably low. There is no management appliance VM, no per-node controller VM, and no separate storage software to feed. The specifications below cover what VergeOS itself needs; you will add capacity on top for your workloads.

{% hint style="info" %}
**Coming from VMware or Nutanix?**

VergeOS has no management appliance VM and no per-node storage VM (no CVM), so the 16 GB minimum RAM is the entire management-plane footprint per node. vSAN RAM (1 GB per 1 TB of storage) is additional, sized to the disk capacity each node contributes.
{% endhint %}

## Generic Requirements (All Node Types)

Every node in a VergeOS cluster -- regardless of role -- must meet these baseline requirements:

| Component             | Minimum Specification                                                                                |
| --------------------- | ---------------------------------------------------------------------------------------------------- |
| **CPU**               | AMD or Intel x86-64 with hardware virtualization support (VT-x / AMD-V)                              |
| **RAM**               | 16 GB dedicated to VergeOS (additional RAM sized for workloads)                                      |
| **Remote Management** | IPMI, iDRAC, iLO, or equivalent out-of-band management                                               |
| **Disk Controller**   | NVMe direct-attached (preferred), or HBA / RAID controller in JBOD / IT mode -- **no hardware RAID** |
| **External NIC**      | 1 x 1 GbE (Intel, NVIDIA Mellanox, or Broadcom)                                                      |
| **Core Fabric NIC**   | 1 x 10 GbE (Intel, NVIDIA Mellanox, or Broadcom)                                                     |

{% hint style="warning" %}
**No Hardware RAID**

VergeOS manages data redundancy through its built-in vSAN (VergeFS). Hardware RAID controllers must be placed in **JBOD or IT mode** so that VergeOS can see and manage individual disks. Using RAID arrays hides disk health information and prevents VergeOS from performing its own data protection.
{% endhint %}

### BIOS Settings Checklist

Before installation, verify these BIOS settings on every node:

* **Boot mode:** UEFI (required if all drives are NVMe)
* **Hardware-assisted virtualization:** Enabled (VT-x / AMD-V)
* **Hyper-threading / SMT:** Enabled
* **All processor cores:** Enabled
* **System clocks:** Synchronized across all nodes (within seconds)
* **Secure Boot:** Disabled

## Controller Nodes (Node 1 and Node 2)

The first two nodes in any VergeOS system are the **controller nodes**. They host the vSAN metadata (Tier 0), manage cluster orchestration, and serve as the system's management plane. Every VergeOS installation requires at least two controller nodes: two controllers provide N+1 redundancy (the default). Surviving the simultaneous loss of two controllers — N+2 (RF3, three copies of every data block) — requires three controller nodes, and five is recommended for N+2 to provide a witness and avoid split-brain scenarios.

### Minimum Specifications

| Component           | Specification                                                                                 | Notes                                           |
| ------------------- | --------------------------------------------------------------------------------------------- | ----------------------------------------------- |
| **CPU**             | 1 x 2.7 GHz+                                                                                  | Higher clock speed benefits metadata operations |
| **RAM**             | 16 GB + 1 GB per 1 TB of storage                                                              | The 1 GB/TB ratio is for vSAN metadata overhead |
| **Tier 0 Storage**  | 2 x Enterprise SSD per controller on N+1; 3 on N+2 for full local protection (1 DWPD minimum) | Stores the vSAN hash map and filesystem index   |
| **Tier 0 Capacity** | 5 GB per 1 TB of usable capacity (baseline)                                                   | Absorbs default 7 snapshots at any change rate  |

### Recommended Specifications

| Component           | Specification                     | Notes                                                           |
| ------------------- | --------------------------------- | --------------------------------------------------------------- |
| **CPU**             | 1 x 3.0 GHz+                      | Improves metadata and orchestration performance                 |
| **Tier 0 Capacity** | 10 GB per 1 TB of usable capacity | For moderate to high change rates with 25-30 retained snapshots |

{% hint style="success" %}
**Tier 0 Is Metadata Only**

Tier 0 stores the vSAN hash map and filesystem index — it is **not** a workload data tier. It lives on fast SSD specifically for performance: keeping the dedup hash map and filesystem index on low-latency media ensures fast lookups across the entire storage pool.

**Endurance and capacity trade-off:** Tier 0 needs high write endurance. The minimum is **1 DWPD**, but endurance scales with capacity (DWPD × capacity = writes/day). This creates an equivalence: you can satisfy Tier 0's endurance requirement with either higher DWPD on smaller capacity, or lower DWPD on larger capacity. For example, 5 GB/TB at 3 DWPD and 15 GB/TB at 1 DWPD both absorb the same total writes per day. The larger, lower-DWPD drive is often the better choice — typically cheaper and more available, with capacity headroom as a bonus.

**Capacity requirement:** the baseline is about **5 GB of usable Tier 0 per 1 TB of usable Tier 1–5 capacity** (after redundancy). This baseline absorbs the default 7 retained snapshots at any change rate. For most systems with a **low to moderate change rate**, the baseline can also hold about **25–30 snapshots**. Systems with **moderate to high change rate** should increase to about **10 GB per 1 TB** when retaining 25–30 snapshots. For detailed guidance on metadata sizing, including the equivalence calculations and when to increase capacity, see the [Tier 0 (metadata) sizing](/plan-and-deploy/implementation-guide/sizing.md#tier-0-metadata-sizing) section in the node sizing guide.

**Media:** Tier 0 does not have to be NVMe. Enterprise SAS SSD is acceptable when it meets the endurance and capacity requirements. For Small/Edge deployments, on all-flash 1-2 node systems, a dedicated Tier 0 device is often unnecessary — metadata can reside on the primary tier.

**Local redundancy:** usable Tier 0 is raw capacity divided by the number of local copies. VergeOS mirrors metadata across local drives: 2 copies on N+1, 3 copies on N+2. Install 2 Tier 0 drives per controller on N+1 and 3 on N+2 for full local protection. See [Local Node Tier 0 Metadata Redundancy](/run-the-platform/storage/tier0-local-redundancy.md) for details.
{% endhint %}

## Storage Nodes

Storage nodes participate in the vSAN and contribute disk capacity to the shared storage pool. In an HCI deployment, storage nodes also run workloads. In a UCI deployment, they may be dedicated exclusively to storage.

### Minimum Specifications

| Component                           | Specification                                     | Notes                                                                                                                                                                                                                               |
| ----------------------------------- | ------------------------------------------------- | ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
| **CPU**                             | 2.7 GHz+                                          | Handles vSAN I/O processing                                                                                                                                                                                                         |
| **RAM**                             | 16 GB + 1 GB per 1 TB of raw storage              | Per-node; scales with disk capacity                                                                                                                                                                                                 |
| **Primary Storage**                 | 1 x Enterprise NVMe or SAS/SATA SSD per node      | For workload I/O (primary storage tier)                                                                                                                                                                                             |
| **Capacity/Archive Tier (Tier 4+)** | Enterprise HDDs (optional)                        | For snapshots, archives, or file-based services. VergeOS does not auto-tier (no automatic data movement), but an administrator can change a volume's or file's preferred tier, which triggers a non-disruptive background migration |
| **Redundancy**                      | At least 2 nodes with matching disk configuration | Required for vSAN data redundancy                                                                                                                                                                                                   |

### Recommended Specifications

| Component           | Specification                                     | Notes                                                                                                                                                            |
| ------------------- | ------------------------------------------------- | ---------------------------------------------------------------------------------------------------------------------------------------------------------------- |
| **CPU**             | 3.0 GHz+, 1 core per disk                         | Count Tier 0 devices as storage disks; do not count boot devices. Use physical CPU cores only; hardware threads (hyperthreading/SMT) do not count as extra cores |
| **RAM**             | 1.5 GB per 1 TB of storage per node               | Better performance under heavy workloads                                                                                                                         |
| **Primary Storage** | 2+ NVMe or SAS/SATA SSDs per node                 | More spindles = more IOPS                                                                                                                                        |
| **Redundancy**      | At least 2 nodes with matching disk configuration | Required for vSAN data redundancy                                                                                                                                |

### RAM Sizing Example

To illustrate the RAM calculation for a storage node:

```
Base VergeOS requirement:          16 GB
Storage overhead (8 TB raw x 1 GB): 8 GB
Workload VMs (example):           96 GB
─────────────────────────────────────────
Total RAM per node:              120 GB
```

At the recommended 1.5 GB/TB ratio, the storage overhead would be 12 GB instead of 8 GB, bringing the total to 124 GB.

{% hint style="info" %}
**Account for the Target Max RAM % (default 80%)**

VergeOS targets no more than **80% of physical RAM** in use per node under normal conditions (the `Target Max RAM %` cluster setting), leaving headroom that failover and live migration can draw on. Size physical RAM so that overhead **plus** workloads fit within that 80%. In the example above, \~120 GB of normal usage should land on a node with at least \~150 GB of physical RAM (120 ÷ 0.80) to stay within the target.
{% endhint %}

## Compute-Only Nodes

Compute-only nodes run workloads but do **not** participate in the vSAN. They have no local storage requirements beyond a boot device (or can PXE boot). This makes them ideal for scaling CPU and RAM independently from storage in UCI and HCI+Compute architectures.

| Component      | Specification                                               |
| -------------- | ----------------------------------------------------------- |
| **CPU**        | Sized for workload requirements                             |
| **RAM**        | Sized for workload requirements (16 GB minimum for VergeOS) |
| **Storage**    | Boot device only (or PXE boot) -- no vSAN disks             |
| **Networking** | Same generic NIC requirements as all nodes                  |

Compute-only nodes are the simplest to size: determine the aggregate CPU and RAM your workloads need, divide by the per-node capacity, and round up to maintain N+1 availability.

## Networking Recommendations

The minimum networking configuration (1 GbE external + 1 x 10 GbE core) is suitable for small or proof-of-concept deployments. For production environments, follow these recommendations:

### Core Fabric NICs

**2 x 25/40/100 GbE** (Intel, NVIDIA Mellanox, or Broadcom). Dual NICs provide redundancy for the core fabric -- the high-speed mesh that carries vSAN replication, VM migration, and inter-node traffic. Jumbo frames are required on the core fabric: VergeOS sets node NICs to \~9192, and the switch ports they connect to must be configured for ≥9216 so those frames pass without fragmentation.

### External NICs

**2 x 10/25/40/100 GbE** (Intel, NVIDIA Mellanox, or Broadcom). Dual external NICs support bonding for redundancy and bandwidth to the upstream network. These carry management UI access and tenant external traffic.

### Supported NIC Vendors

VergeOS supports network adapters from three vendors:

* **Intel** -- Broad compatibility across different series
* **NVIDIA Mellanox** -- High-performance ConnectX series
* **Broadcom** -- Enterprise-grade NICs

{% hint style="warning" %}
Consumer-grade or off-brand NICs are not supported. Using unsupported NICs may result in driver compatibility issues, poor performance, or system instability.
{% endhint %}

## Storage Warnings and Considerations

### Consumer-Grade Disks

{% hint style="danger" %}
**Consumer-Grade Disks Not Supported**

VergeOS does **not** officially support consumer-grade disks. Only enterprise-grade storage devices should be used in production environments and backups of production data. Consumer-grade disks may be acceptable for test, development, or proof-of-concept environments where data loss is tolerable. Some consumer-grade devices may not function properly due to firmware limitations, non-standard command implementations, or compatibility issues with VergeOS.
{% endhint %}

### Large HDD Considerations

HDDs larger than **8 TB** are not recommended outside of archive-specific environments. The concern is **rebuild time**. vSAN does not rebuild automatically when a drive fails — an operator kicks off a repair that rebuilds the lost data onto a hot spare or replacement drive. With an 8 TB+ drive, that rebuild can take many hours — often days — during which:

* **System performance is degraded** as rebuild I/O competes with production workloads
* **Availability risk increases** because a second drive failure during rebuild could cause data loss
* **The rebuild window grows** proportionally with drive size

For primary workload tiers, prefer smaller, faster SSDs. Reserve large HDDs for snapshot retention, archival storage, or file-based service tiers where rebuild time is an acceptable trade-off.

### Fibre Channel LUNs as Storage

VergeOS vSAN can also consume **Fibre Channel (FC) LUNs** as storage devices within its tiers, which is useful for integrating existing SAN investments. VergeOS treats each FC LUN like a local physical disk, so native redundancy and deduplication still apply. Key requirements:

* Present **unique LUNs per node** — never share the same LUN across multiple nodes
* FC HBAs in at least two nodes; a redundant FC fabric is recommended
* **Disable RAID and auto-tiering on the SAN** — VergeOS handles redundancy natively
* Keep **Tier 0 metadata on direct-attached NVMe** — external storage is not recommended for Tier 0

Verge.io still recommends direct-attached disks for best performance and simplicity; use FC LUNs primarily when you have existing SAN infrastructure or specific compliance requirements. See [Using Fibre Channel Storage with vSAN](/run-the-platform/storage/fibre-channel.md) for setup details.

## Dedicated vs. Shared Controller Nodes

VergeOS supports flexible node role design. Controller, storage, and compute roles can be combined on the same physical nodes depending on hardware availability, workload density, and deployment scale. **Most systems use nodes that serve multiple roles** — for example, nodes that are both controllers and storage participants. Smaller environments may run controller, storage, and compute workloads on the same nodes.

**Dedicated controller nodes** — nodes that handle only the vSAN metadata (Tier 0) and system management, without running guest workloads or contributing to workload storage tiers — are an optional design choice. Similarly, dedicated storage-only or compute-only nodes are optional design choices, not a requirement for every deployment.

```mermaid
graph LR
    subgraph shared["Combined Roles (Default / Small Systems)"]
        N1S["Node 1<br/>Controller + Storage + Compute"]
        N2S["Node 2<br/>Controller + Storage + Compute"]
    end

    subgraph dedicated["Dedicated Controllers (Optional)"]
        N1D["Node 1<br/>Controller Only<br/>(Tier 0 metadata)"]
        N2D["Node 2<br/>Controller Only<br/>(Tier 0 metadata)"]
        N3["Node 3+<br/>Storage + Compute"]
        N4["Node 4+<br/>Storage + Compute"]
    end

    style shared fill:#d1fae5,stroke:#059669
    style dedicated fill:#fef3c7,stroke:#d97706
```

| Approach                  | When to Use                       | Trade-off                                                         |
| ------------------------- | --------------------------------- | ----------------------------------------------------------------- |
| **Combined roles**        | Most systems, smaller deployments | Fewer nodes, simpler design                                       |
| **Dedicated controllers** | Optional design choice            | Extra nodes, but metadata operations are isolated and predictable |

## Sizing Quick Reference

Use this quick-reference card when scoping a new deployment:

| Question                         | Guidance                                                                                                                                                                                              |
| -------------------------------- | ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
| How much RAM per storage node?   | 16 GB base + 1 GB per 1 TB raw (minimum) or 1.5 GB per 1 TB (recommended)                                                                                                                             |
| How many Tier 0 drives?          | 2 per controller on N+1; 3 per controller on N+2 for full local protection                                                                                                                            |
| How large should Tier 0 be?      | 5 GB/TB usable (baseline, absorbs default 7 snapshots at any change rate and can hold 25-30 snapshots at low to moderate change rate); 10 GB/TB for moderate to high change rate with 25-30 snapshots |
| What endurance for Tier 0?       | Minimum 1 DWPD; size Tier 0 so write budget ≈ 15 GB/TB/day (e.g. 5 GB/TB @ 3 DWPD or 15 GB/TB @ 1 DWPD).                                                                                              |
| What media for Tier 0?           | Enterprise SSD (NVMe or SAS); dedicated Tier 0 often unnecessary on all-flash 1-2 node systems                                                                                                        |
| How many cores per storage disk? | 1 core per disk (recommended)                                                                                                                                                                         |
| Minimum nodes for vSAN?          | 2 nodes with matching disk configuration                                                                                                                                                              |
| Core fabric NIC speed?           | 10 GbE minimum; 25/100 GbE recommended                                                                                                                                                                |

## Next Steps

Now that you understand the hardware requirements for each node role, continue to:

* [**Reference Architectures**](/learn-the-platform/module-2-sizing-and-design/02-reference-architectures.md) -- See how these requirements map to real-world deployment topologies (HCI, HCI+Compute, UCI)
* [**Customer Scoping**](/learn-the-platform/module-2-sizing-and-design/03-customer-scoping.md) -- Learn the methodology for translating customer workloads into hardware specifications


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://docs.verge.io/learn-the-platform/module-2-sizing-and-design/01-hardware-requirements.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.