For the complete documentation index, see llms.txt. This page is also available as Markdown.

Hardware Requirements

Minimum and recommended hardware specifications for VergeOS controller nodes, storage nodes, and compute-only nodes, plus maximum supported limits.

Overview

Sizing a VergeOS deployment starts with understanding the hardware requirements for each node role. Because VergeOS is a complete infrastructure operating system -- not a collection of separate products -- its base overhead is remarkably low. There is no management appliance VM, no per-node controller VM, and no separate storage software to feed. The specifications below cover what VergeOS itself needs; you will add capacity on top for your workloads.

Coming from VMware or Nutanix?

VergeOS has no management appliance VM and no per-node storage VM (no CVM), so the 16 GB minimum RAM is the entire management-plane footprint per node. vSAN RAM (1 GB per 1 TB of storage) is additional, sized to the disk capacity each node contributes.

Generic Requirements (All Node Types)

Every node in a VergeOS cluster -- regardless of role -- must meet these baseline requirements:

Component
Minimum Specification

CPU

AMD or Intel x86-64 with hardware virtualization support (VT-x / AMD-V)

RAM

16 GB dedicated to VergeOS (additional RAM sized for workloads)

Remote Management

IPMI, iDRAC, iLO, or equivalent out-of-band management

Disk Controller

NVMe direct-attached (preferred), or HBA / RAID controller in JBOD / IT mode -- no hardware RAID

External NIC

1 x 1 GbE (Intel, NVIDIA Mellanox, or Broadcom)

Core Fabric NIC

1 x 10 GbE (Intel, NVIDIA Mellanox, or Broadcom)

BIOS Settings Checklist

Before installation, verify these BIOS settings on every node:

  • Boot mode: UEFI (required if all drives are NVMe)

  • Hardware-assisted virtualization: Enabled (VT-x / AMD-V)

  • Hyper-threading / SMT: Enabled

  • All processor cores: Enabled

  • System clocks: Synchronized across all nodes (within seconds)

  • Secure Boot: Disabled

Controller Nodes (Node 1 and Node 2)

The first two nodes in any VergeOS system are the controller nodes. They host the vSAN metadata (Tier 0), manage cluster orchestration, and serve as the system's management plane. Every VergeOS installation requires at least two controller nodes: two controllers provide N+1 redundancy (the default). Surviving the simultaneous loss of two controllers — N+2 (RF3, three copies of every data block) — requires three controller nodes, and five is recommended for N+2 to provide a witness and avoid split-brain scenarios.

Minimum Specifications

Component
Specification
Notes

CPU

1 x 2.7 GHz+

Higher clock speed benefits metadata operations

RAM

16 GB + 1 GB per 1 TB of storage

The 1 GB/TB ratio is for vSAN metadata overhead

Tier 0 Storage

1 x Enterprise NVMe SSD (3 DWPD or equivalent)

Stores the vSAN hash map and filesystem index

Tier 0 Capacity

5 GB per 1 TB of usable capacity

Dedicated metadata storage

Component
Specification
Notes

CPU

1 x 3.0 GHz+

Improves metadata and orchestration performance

Tier 0 Storage

2 x Enterprise NVMe SSD (3 DWPD or equivalent)

Redundant metadata configuration

Tier 0 Capacity

10 GB per 1 TB of usable capacity

Additional headroom for metadata growth

Storage Nodes

Storage nodes participate in the vSAN and contribute disk capacity to the shared storage pool. In an HCI deployment, storage nodes also run workloads. In a UCI deployment, they may be dedicated exclusively to storage.

Minimum Specifications

Component
Specification
Notes

CPU

2.7 GHz+

Handles vSAN I/O processing

RAM

16 GB + 1 GB per 1 TB of raw storage

Per-node; scales with disk capacity

Primary Storage

1 x Enterprise NVMe or SAS/SATA SSD per node

For workload I/O (primary storage tier)

Capacity/Archive Tier (Tier 4+)

Enterprise HDDs (optional)

For snapshots, archives, or file-based services. VergeOS does not auto-tier (no automatic data movement), but an administrator can change a volume's or file's preferred tier, which triggers a non-disruptive background migration

Redundancy

At least 2 nodes with matching disk configuration

Required for vSAN data redundancy

Component
Specification
Notes

CPU

3.0 GHz+, 1 core per disk

Dedicated core per disk improves I/O throughput

RAM

1.5 GB per 1 TB of storage per node

Better performance under heavy workloads

Primary Storage

2+ NVMe or SAS/SATA SSDs per node

More spindles = more IOPS

Redundancy

At least 2 nodes with matching disk configuration

Required for vSAN data redundancy

RAM Sizing Example

To illustrate the RAM calculation for a storage node:

At the recommended 1.5 GB/TB ratio, the storage overhead would be 12 GB instead of 8 GB, bringing the total to 124 GB.

Account for the Target Max RAM % (default 80%)

VergeOS targets no more than 80% of physical RAM in use per node under normal conditions (the Target Max RAM % cluster setting), leaving headroom that failover and live migration can draw on. Size physical RAM so that overhead plus workloads fit within that 80%. In the example above, ~120 GB of normal usage should land on a node with at least ~150 GB of physical RAM (120 ÷ 0.80) to stay within the target.

Compute-Only Nodes

Compute-only nodes run workloads but do not participate in the vSAN. They have no local storage requirements beyond a boot device (or can PXE boot). This makes them ideal for scaling CPU and RAM independently from storage in UCI and HCI+Compute architectures.

Component
Specification

CPU

Sized for workload requirements

RAM

Sized for workload requirements (16 GB minimum for VergeOS)

Storage

Boot device only (or PXE boot) -- no vSAN disks

Networking

Same generic NIC requirements as all nodes

Compute-only nodes are the simplest to size: determine the aggregate CPU and RAM your workloads need, divide by the per-node capacity, and round up to maintain N+1 availability.

Networking Recommendations

The minimum networking configuration (1 GbE external + 1 x 10 GbE core) is suitable for small or proof-of-concept deployments. For production environments, follow these recommendations:

Core Fabric NICs

2 x 25/40/100 GbE (Intel, NVIDIA Mellanox, or Broadcom). Dual NICs provide redundancy for the core fabric -- the high-speed mesh that carries vSAN replication, VM migration, and inter-node traffic. Jumbo frames are required on the core fabric: VergeOS sets node NICs to ~9192, and the switch ports they connect to must be configured for ≥9216 so those frames pass without fragmentation.

External NICs

2 x 10/25/40/100 GbE (Intel, NVIDIA Mellanox, or Broadcom). Dual external NICs support bonding for redundancy and bandwidth to the upstream network. These carry management UI access and tenant external traffic.

Supported NIC Vendors

VergeOS supports network adapters from three vendors:

  • Intel -- Broad compatibility across different series

  • NVIDIA Mellanox -- High-performance ConnectX series

  • Broadcom -- Enterprise-grade NICs

Maximum Supported Specifications

The following table outlines the maximum supported hardware specifications as of VergeOS version 4.12:

Resource
Maximum
Notes

Nodes per system

200

Across all clusters

Individual physical disk size

64 TB

Per physical drive

RAM per host

5 TB

vSAN nodes require 1 GB RAM per 1 TB storage

vDisk size

256 TB

Per virtual disk

Disks per VM

2,000

Requires Virtio-SCSI interface

Clusters per system

100

Mix of compute, storage, and HCI clusters

Storage tiers per system

5

5 workload tiers (Tier 1 high-performance through Tier 5 archive); Tier 0 metadata is separate and system-only

vSAN fault domains per system

2

Provides data redundancy

These limits accommodate extremely large-scale deployments. Most production environments operate well within these boundaries.

Storage Warnings and Considerations

Consumer-Grade Disks

Large HDD Considerations

HDDs larger than 8 TB are not recommended outside of archive-specific environments. The concern is rebuild time. vSAN does not rebuild automatically when a drive fails — an operator kicks off a repair that rebuilds the lost data onto a hot spare or replacement drive. With an 8 TB+ drive, that rebuild can take many hours — often days — during which:

  • System performance is degraded as rebuild I/O competes with production workloads

  • Availability risk increases because a second drive failure during rebuild could cause data loss

  • The rebuild window grows proportionally with drive size

For primary workload tiers, prefer smaller, faster SSDs. Reserve large HDDs for snapshot retention, archival storage, or file-based service tiers where rebuild time is an acceptable trade-off.

Fibre Channel LUNs as Storage

VergeOS vSAN can also consume Fibre Channel (FC) LUNs as storage devices within its tiers, which is useful for integrating existing SAN investments. VergeOS treats each FC LUN like a local physical disk, so native redundancy and deduplication still apply. Key requirements:

  • Present unique LUNs per node — never share the same LUN across multiple nodes

  • FC HBAs in at least two nodes; a redundant FC fabric is recommended

  • Disable RAID and auto-tiering on the SAN — VergeOS handles redundancy natively

  • Keep Tier 0 metadata on direct-attached NVMe — external storage is not recommended for Tier 0

Verge.io still recommends direct-attached disks for best performance and simplicity; use FC LUNs primarily when you have existing SAN infrastructure or specific compliance requirements. See Using Fibre Channel Storage with vSAN for setup details.

Dedicated vs. Shared Controller Nodes

For production environments, VergeOS recommends dedicated controller nodes -- nodes that handle only the vSAN metadata (Tier 0) and system management, without running guest workloads or contributing to workload storage tiers.

Approach
When to Use
Trade-off

Shared controllers

2-node clusters, PoC, dev/test

Fewer nodes, but metadata I/O competes with workloads

Dedicated controllers

Production, 4+ nodes

Extra nodes, but metadata operations are isolated and predictable

Sizing Quick Reference

Use this quick-reference card when scoping a new deployment:

Question
Guidance

How much RAM per storage node?

16 GB base + 1 GB per 1 TB raw (minimum) or 1.5 GB per 1 TB (recommended)

How many Tier 0 drives?

1 per controller (minimum), 2 per controller (recommended)

How large should Tier 0 be?

5 GB per 1 TB usable (minimum), 10 GB per 1 TB usable (recommended)

What DWPD for Tier 0?

3 DWPD or equivalent (enterprise NVMe)

How many cores per storage disk?

1 core per disk (recommended)

Minimum nodes for vSAN?

2 nodes with matching disk configuration

Maximum nodes per system?

200

Core fabric NIC speed?

10 GbE minimum; 25/100 GbE recommended