vSAN / VergeFS: Software-Defined Storage
Understand how VergeOS vSAN (VergeFS) provides distributed, software-defined storage with tiered architecture, hash-based data distribution, and self-healing redundancy.
What is vSAN / VergeFS?
vSAN (Virtual Storage Area Network), also known as VergeFS, is the software-defined distributed storage system built into every VergeOS deployment. It pools the physical (or virtual) drives across all storage-participating nodes into a single, shared storage resource for the entire system.
There is no external SAN, NAS, or third-party storage software required. vSAN is integrated directly into the VergeOS platform and operates at the block level, providing storage for all VM disks, snapshots, ISO images, and system metadata.
Key characteristics:
Block-level architecture — VM disks are divided into blocks, each identified by a content-addressable hash
Distributed across nodes — Data blocks are spread across all storage-participating nodes in the cluster
Tiered storage — Tier 0 is reserved for vSAN metadata; Tiers 1–5 are workload storage tiers that let you match media type to workload requirements
Inline deduplication — Hash-based block identification enables automatic deduplication across all tiers
Self-healing — Automatic failure detection and failover to redundant copies. Rebuild is operator-initiated (hot spare or hardware replacement); Journal Walks then re-replicate the missing blocks from redundant copies. Self-healing operates within the configured redundancy level (N+1 or N+2); failures that exceed redundancy (e.g., simultaneous loss of more nodes than the system can tolerate) may result in stuck repairs requiring manual intervention and support engagement
The Tier System
VergeOS vSAN organizes drives into tiers numbered 0 through 5. Each tier is designed for a different class of storage media and workload profile. During installation, each physical drive is assigned to a specific tier, and that assignment determines how the drive is used by the system.
Tier 0: Metadata
Hardware: High-endurance NVMe SSDs
Purpose: Stores the vSAN filesystem index and internal metadata exclusively
Key requirement: Tier 0 lives only on controller nodes — nodes 1–2 for N+1, or nodes 1–3 for N+2
Best practice: Use enterprise NVMe drives rated for 3 DWPD (Drive Writes Per Day) or equivalent (i.e. if you only need 500 GB for vSAN metadata, a larger 2 TB drive rated at 1 DWPD provides comparable total write endurance); maintain at least 30% free space on Tier 0
Tiers 1–5: Workload Data
Tier 1
High-endurance NVMe SSDs
Write-intensive workloads
High-performance databases, transaction logs
Tier 2
Mid-range SSDs
Balanced read/write workloads
General-purpose VMs, mixed applications, dev environments
Tier 3
Read-optimized SSDs
Read-intensive workloads
Content delivery, application repos, reference data
Tier 4
High-capacity HDDs
Less frequently accessed data
File servers, backup targets
Tier 5
Archival-grade HDDs
Cold storage and long-term retention
Compliance archives, backup archives
Not every deployment uses all five workload tiers. A common production configuration might use only tier 1 (NVMe for performance-sensitive workloads) and tier 4 (HDD for capacity). The Terraform playground uses tier 0 and tier 1 only.
How Data is Distributed
vSAN uses a hash-based distribution algorithm to spread data blocks across all nodes in the cluster. Here is how it works:
Block Creation and Hashing
When a VM writes data, vSAN divides the write into data blocks
Each block is assigned a content-addressable hash that serves as its unique identifier
The hash determines both the block's storage location and enables deduplication — if two blocks produce the same hash, only one copy is stored
Cross-Node Distribution
Data blocks are distributed across multiple nodes in the cluster rather than stored on a single node. This design provides:
Balanced performance — I/O load is spread across all storage-participating nodes
Fault tolerance — No single node holds all copies of any dataset
Efficient scaling — Adding a node automatically expands the storage pool and triggers rebalancing
Read and Write Paths
Reads:
The system looks up the block's location via the tier-0 hash map
Reads prioritize the primary copy for efficiency
If the VM is running on the same node as a redundant copy, vSAN reads the local copy to minimize network traffic
If the primary copy is slow or unresponsive, vSAN automatically fails over to the redundant copy
Writes:
New blocks are hashed and placed on the optimal node
Both the primary and redundant copies are written simultaneously
Write is only acknowledged after both copies are confirmed
The tier-0 metadata is updated to track the new block's location
Redundancy and Self-Healing
vSAN maintains multiple copies of every data block to protect against hardware failures. The redundancy level — also known as the Replication Factor (RF) — is configured at the system level and applies per tier. RF is simply the number of copies kept: RF2 (N+1) keeps 2 copies, RF3 (N+2) keeps 3.
Redundancy Levels
Copies of data
2
3
Simultaneous failures tolerated
1 node
2 nodes
Minimum controller nodes
2
3
Recommended nodes
3
5
Storage overhead (before dedup)
~2×
~3×
N+1 (RF2) is the default and is suitable for most production environments
N+2 (RF3) is available for ultra-critical workloads or remote sites where hardware replacement is slow
Redundancy level is typically set during installation and applies system-wide
A failure only affects the tier where the failed drives reside — other tiers remain fully operational
Self-Healing Process
When a node or drive fails, vSAN automatically fails over to redundant copies — VMs keep running with no downtime, but the affected tier operates at reduced redundancy. Restoring full redundancy is operator-driven: either kick off a repair against a designated hot spare, or replace the failed drive (or node) and the rebuild begins from there:
Detection — vSAN detects the drive or node failure automatically; the topology change triggers a Full Journal Walk that re-verifies redundancy across the affected tier
Failover — Reads and writes are redirected to redundant copies with no VM downtime
Reduced redundancy — The affected tier operates without full redundancy until an operator intervenes
Rebuild — An operator either initiates a repair against a designated hot spare, or replaces the failed drive/node. vSAN then re-replicates the affected blocks to restore full redundancy
Drive Assignment in Practice
During VergeOS installation, each physical drive is assigned to a specific vSAN tier. The installer uses the YC_DRIVE_LIST and YC_VSAN_TIER_LIST variables (set interactively during installation) to map drives to tiers.
Assignment Rules
Tier 0 placement: Tier 0 lives only on controller nodes — nodes 1–2 for N+1, or nodes 1–3 for N+2
Drives within the same tier should be of similar type and performance characteristics
When scaling up (adding drives), add equal drives across all nodes in the cluster to maintain balanced distribution
When scaling out (adding nodes), new nodes should match the existing cluster's hardware configuration (CPU, memory, disk layout)
Example: 2-Node HCI Configuration
In the Terraform playground's simplest deployment, each controller node has:
1× NVMe (small)
Tier 0
Metadata — vSAN hash map and filesystem index
1× NVMe (large)
Tier 1
Workload data — VM disks, snapshots, ISOs
Both nodes contribute their drives to the same vSAN pool. With N+1 redundancy (default), every block written to tier 1 on node 1 has a redundant copy on node 2, and vice versa.
Additional vSAN Features
Inline Deduplication
Because every data block is identified by its cryptographic hash, vSAN automatically detects duplicate blocks. If two VMs (or two regions within the same VM disk) write identical data, only one copy of that block is stored. This operates inline — during the write path — with no separate deduplication job or schedule.
Encryption
vSAN supports AES-256 encryption at rest, configured during initial installation. Encryption keys can be stored on USB drives (plugged into the first two controller nodes) or entered manually at boot time. All data across all tiers is encrypted transparently.
Snapshots and Clones
vSAN's block-level architecture enables space-efficient snapshots — a snapshot records the hash map state at a point in time rather than copying data blocks. Clones similarly reference existing blocks, only consuming additional space when data diverges.
Key Takeaways
vSAN / VergeFS
Built-in distributed storage — no external SAN/NAS required
Tier 0
Metadata only (NVMe). Lives only on controller nodes (1–2 for N+1, 1–3 for N+2).
Tiers 1–5
Workload data, from high-performance NVMe to archival HDD
Data distribution
Hash-based, spread across all storage nodes
Redundancy
N+1 (2 copies, default) or N+2 (3 copies) — system-wide per tier
Self-healing
Automatic failover on failure; rebuild is operator-driven (hot spare or replacement)
Deduplication
Inline, hash-based, across all tiers
Compression
Not at rest — only during site-sync replication
Next Steps