VergeOS Update Instructions

Step-by-step instructions for updating a VergeOS environment with zero downtime, including troubleshooting common update issues.

The VergeOS platform supports 'zero downtime' updating. This means that during a routine update process, guest workloads (VMs and tenant environments) can remain on and running as normal.

For more information on the update process, please refer to our Product Guide.

The time required to complete an update varies depending on factors such as:

  • Number of nodes in the system

  • Storage consumed on the vSAN

  • Data change rate generated by workloads during the update

  • Hardware performance (processor speed, disk type, network speed)

Update Procedure

  1. Log in to the VergeOS UI.

  2. Navigate to System > Updates, then select Check for Updates in the left menu.

    • A pop-up will prompt Yes or No, select Yes.

    • If a banner appears stating "A new minor version is available on a different branch," follow the prompt to change branches by selecting Change Branch in the left menu. Confirm with Yes. VergeOSupgrade-new-img2.png

  3. The packages to be downloaded will now be highlighted. VergeOSupgrade-new-img3.png

    • Select Download in the left menu.

    • A pop-up will prompt Yes or No, select Yes.

    • The download process will appear on the dashboard in the Current Update Server tile.

  4. Once the download completes, the Install action will become available.

    • Select Install when ready.

    • Confirm with Yes to begin the install.

  5. After installation, a request to reboot the system will occur.

    • Select Reboot in the left menu to initiate a rolling reboot across all nodes.

Note

The update will start with Node 1, putting it into maintenance mode and migrating workloads to another node. During minor version changes, you may briefly lose access to the UI as it fails back to Node 1. This is normal and should last no more than a minute or two. Workloads should not experience network issues.

Troubleshooting Steps

Workloads Failing to Migrate

  • This error is usually due to insufficient resources (RAM) in the cluster. Try migrating other workloads or adjust RAM usage. More causes and solutions are detailed here.

vSAN Taking a Long Time to Verify

  • The verification process depends on factors like network speed, disk type, and consumed data. HDDs will take longer than NVMe or SSDs. On VergeOS versions 4.9.0 and higher, check the Full Walk Progress on the tiers dashboard for an indication of how far along the verification is.

    walk-percentage.png

Unable to Connect to Update Server

  • Ensure the system has a working DNS server on its external (UI) network:

    1. Navigate to the external network dashboard.

    2. Select Diagnostics in the left menu.

    3. Set Query to DNS Lookup and select Send.

    4. If DNS is properly configured, the response will display Verge.io's IP address. If not, check DNS settings and retry the query.

  • Expired Update Server credentials can also cause this issue. These are tied to the system's license and should be renewed through your VergeOS sales representative.


Document Information

  • Last Updated: 2024-09-03

  • VergeOS Version: 4.12.6