Adding Tier 0 to an Existing System
Step-by-step guide for adding Tier 0 metadata storage to an existing VergeOS system that was not configured with Tier 0 during initial installation.
Last updated
Was this helpful?
Step-by-step guide for adding Tier 0 metadata storage to an existing VergeOS system that was not configured with Tier 0 during initial installation.
Key Points
Tier 0 is normally configured during initial installation
This procedure is for special cases requiring post-installation configuration
Requires careful attention to device paths and hardware compatibility
This guide outlines the process for adding Tier 0 storage to an existing VergeOS system. While Tier 0 is typically configured during installation, these steps provide a method for adding it to production systems that cannot be reinstalled.
Critical Warning
This procedure should only be performed by qualified VergeOS engineers or under direct support guidance
Selected devices will be formatted and all existing data will be destroyed
Incorrect device path selection can seriously damage your system
Before beginning this procedure, ensure:
Storage devices are physically installed in the system
Tier 0 devices are consistent across controller nodes
Hardware meets specifications from the Node Sizing Guide
Navigate to System > vSAN Diagnostics.
Select Get Node Device List from the Query dropdown
Click Send
Identify unused devices (marked as "vsan = false")
Note the device paths (/dev/sd*) for each controller node
Verify current vSAN drive assignments by checking vSAN Tiers > [select tier] > Drives to avoid selecting drives already in use.
For each drive:
In vSAN Diagnostics:
Set Query to Add Drive to vSAN
Select the appropriate Node (node0 or node1)
Enter the correct Path for the device
Set Tier to Tier 0
Configure Swap setting
Swap Configuration
Enable swap on only ONE storage tier
If swap is enabled on another tier, disable it for Tier 0
Contact VergeOS Support for guidance on swap configuration if needed
Enter the verification phrase: Yes I know what I'm doing
Click Send to execute
Monitor the system dashboard for tier status
Status will show "online-no redundancy" during meta migration
Refresh node information:
Navigate to each controller node's dashboard
Select Refresh > Drives & NICs
Monitor the vSAN tier status in the system dashboard. The tier should transition from "online-no redundancy" to "online" once meta migration completes.
Document Information
Last Updated: 2024-11-25
VergeOS Version: 4.13