Scaling Up a vSAN
To scale up a vSAN, follow the steps below. However, before proceeding, ensure that your current vSAN has at least 10% free capacity.
Important
- All drives in a tier must be alike. If a drive of an incorrect size is added to an existing tier, the tier will only be able to use the space of the smallest drive.
- Ensure that your vSAN has at least 10% free capacity unless you are doubling the capacity. If the free space is less than 10% and you are not doubling the drive count, consider scaling out by adding a node.
Steps to Scale Up#
-
Physically add the drives or Fiber Channel LUNs on the node you want to scale up.
-
Log in to the host system's UI and select the appropriate cluster you want to scale out from the top compute cluster section on the home page.
-
Select the node that you are scaling up.
-
Refresh the system to recognize the new drives: - Select Refresh from the left menu, and choose Drives & NICs from the dropdown. - Confirm by selecting Yes.
-
Select the Scale Up option on the left menu.
-
The page will now show the newly inserted drives in an offline state. Select the drive(s), then under Node Drives, select the Scale Up function.
-
Select the appropriate tier for the drive(s) and submit.
Upon completion, the screen will refresh and the drives will disappear from the view. Go back to the main page, where you will see the vSAN tiers change color to yellow, indicating that it is in a repair state. This is expected, and the vSAN will return to a green/healthy state after a few minutes, showing the newly added tier or increased space on an existing tier.
Repeat these steps for each node as necessary.
Document Information
- Last Updated: 2024-08-29
- VergeOS Version: 4.13