Adding Tier 0 to an Existing System#

Overview#

Key Points

  • Tier 0 is normally configured during initial installation
  • This procedure is for special cases requiring post-installation configuration
  • Requires careful attention to device paths and hardware compatibility

This guide outlines the process for adding Tier 0 storage to an existing VergeOS system. While Tier 0 is typically configured during installation, these steps provide a method for adding it to production systems that cannot be reinstalled.

Critical Warning

  • This procedure should only be performed by qualified VergeOS engineers or under direct support guidance
  • Selected devices will be formatted and all existing data will be destroyed
  • Incorrect device path selection can seriously damage your system

Prerequisites#

Before beginning this procedure, ensure:

  • Storage devices are physically installed in the system
  • Tier 0 devices are consistent across controller nodes
  • Hardware meets specifications from the Node Sizing Guide

Steps#

1. Identify Device Paths#

  1. Navigate to System > vSAN Diagnostics from the Main Dashboard
  2. Select Get Node Device List from the Query dropdown
  3. Click Send
  4. Identify unused devices (marked as "vsan = false")
  5. Note the device paths (/dev/sd*) for each controller node

Tip

Verify current vSAN drive assignments by checking vSAN Tiers > [select tier] > Drives to avoid selecting drives already in use.

2. Add Drives to Tier 0#

For each drive:

  1. In vSAN Diagnostics:
    • Set Query to Add Drive to vSAN
    • Select the appropriate Node (node0 or node1)
    • Enter the correct Path for the device
    • Set Tier to Tier 0
    • Configure Swap setting

Swap Configuration

  • Enable swap on only ONE storage tier
  • If swap is enabled on another tier, disable it for Tier 0
  • Contact VergeOS Support for guidance on swap configuration if needed
  1. Enter the verification phrase: Yes I know what I'm doing
  2. Click Send to execute

3. Verify Configuration#

  1. Monitor the system dashboard for tier status - Status will show "online-no redundancy" during meta migration
  2. Refresh node information: - Navigate to each controller node's dashboard - Select Refresh > Drives & NICs

Post-Configuration#

Monitor the vSAN tier status in the system dashboard. The tier should transition from "online-no redundancy" to "online" once meta migration completes.

Additional Resources#


Document Information

  • Last Updated: 2024-11-25
  • VergeOS Version: 4.13